PAS · EM133-XM OVER WI-FI

Communication, uploads and RTC

Recorded draft

Watch the lesson

Download MP4 · SRT captions · Use the video controls for captions and fullscreen; Escape returns to this lesson.

Your choice is remembered in this browser. Only available recordings can be selected. Changing version pauses the video and returns to the start. This choice applies to the lesson video, not a separate Short.

Playing version: Michael · en-AU · Australian.

Current complete Australian edition.

Available and planned versions
  • Michael · en-AU · Australian — available
  • Charlotte · en-US · American — planned; recording not available
  • Spanish narration · es · To be selected — planned; recording not available
  • US English narration · en-US · US — planned; recording not available

Chapters

Chapter positions follow the reviewed recording index.

Read the lesson transcript

In this lesson, we verify communication with an EM133-XM over Wi-Fi, in PAS, open monitor, then communication test. This demonstration uses device address 1 and the approved IP address shown on screen. Read one word from firmware register 2565 using function 3. Send the request, inspect the response, then repeat. Both reads return 1210, with no reported communication errors. This checks a stable firmware value. It is not a unique serial number. Next, choose MeterSetup, then Upload Setups. Upload means copying configuration from the meter into the local PAS site file. Check that the selected file is your demonstration site before accepting the overwrite warning. Wait for the upload complete message. Download Setups sends settings in the opposite direction, so do not confuse the two commands. This session reads the configuration without changing CT settings. For the clock, open monitor, then RTC. Compare the computer and device times first. Set synchronises the meter to the computer, an authorised operator completes authentication if required. This edit shows separate before and after shots. After synchronising, select Read again. Here, the displayed times agree. That verifies the read back against this computer. Not an independently calibrated time reference. To retrieve records, open logs, then upload logs. Save into a new log database, separate from the site configuration. In this take, PAS uploads the event log and data log one, and reports 1093 records uploaded. Let the transfer finish before opening the file. The saved database also contains an RTC set event at the synchronisation time. That event was checked directly in the database because navigating the PAS report caused the application to close. upload success and report viewing are separate checks. Pro-tip, while online, right-click the selected site and open properties. Check the model, serial number and firmware before interpreting measurements. Scroll to inspect the connection and configuration. Offline properties may show saved information instead. Another useful tip. If the expected OK button is hidden, Enter can activate the dialog default. In this recording it worked from the file name field. Check the focus and expected action first.

Pro tips, after the menu workflow

Inspect model, serial number and firmware before interpreting measurements. Scroll to inspect connection and configuration. Offline Properties may show saved information.

In this recording, Enter accepted the upload/save dialog from the filename field when the expected OK button was not visible. Check focus and the expected default action first; this is not a universal shortcut.

New: understand and check the meter RTC · Compare clock synchronisation methods

RTC Short

Download MP4 · SRT captions · Use the video controls for captions and fullscreen; Escape returns to this lesson.

What the recording establishes

Communication, configuration upload, RTC readback and log retrieval succeeded in the recorded session. PAS report navigation remains unresolved: the RTC set event was verified separately in the saved database. Upload success does not establish successful report navigation.

The full PAS context, Sites Tree and recorded PAS clock remain visible. Only serial digits are masked for reuse. Upload waiting time is shortened and the held result is labelled. RTC authentication is omitted between separate before and after shots.

No CT settings were changed. This is a recorded workflow, not a measurement-performance or calibrated-time claim.

Revision and review details

Lesson revision 20261108-au-remakes · Course revision 20261107-draft-v1

Technical review recorded as PASS for this media revision. Human listening, editorial acceptance and release are pending.

RevisionChange and reasonReview / supersedes
20261107-ui-v2
7 November 2026
Compact mobile navigation; playable lesson first; collapsible roadmap and review details; chapter controls follow playback and respect reduced motion.

Improve access to the existing recorded draft on a phone. Presentation only: technical instructions, media revision and media hashes are unchanged.

Presentation candidate for protected preview; human listening, editorial acceptance and release remain pending.

Presentation of the initial course navigation proposal.

v02
7 November 2026
Added the On-line prerequisite to the University upload chapter and the Short subtitle. Retained full PAS context, Sites Tree and recorded clock.

Make the prerequisite explicit without altering the recorded meter interaction.

Exact media documentary/technical review recorded as PASS; human listening, editorial acceptance and release pending.

Short v01; only the v02 edits are selected here.

Review basis: the delivery claims register and final review dated 7 November 2026. Media integrity is checked when this preview is built; technical review is not a public release.