PAS · EM133-XM data and event logs

Choose the right EM133-XM log

Written lesson · recorded supplement

Narrated tour

Download MP4 · SRT captions · Use the video controls for captions and fullscreen; Escape returns to this lesson.

Your choice is remembered in this browser. Only available recordings can be selected. Changing version pauses the video and returns to the start. This choice applies to the lesson video, not a separate Short.

Playing version: Michael · en-AU · Australian.

Current complete Australian edition.

Available and planned versions
  • Michael · en-AU · Australian — available
  • Charlotte · en-US · American — planned; recording not available
  • Spanish narration · es · To be selected — planned; recording not available
  • US English narration · en-US · US — planned; recording not available
About this recording

Actual moving PAS saved offline-site inspection, plus separately labelled historical live configuration/log uploads recorded on 7 November 2026. No new configuration write, memory clearing, or Event Log report demonstration. The portrait Short retains full PAS above a same-time detail view.

Michael (Australian) narration from ElevenLabs. Edited PAS screen recording.

Chapters

Feature Short

Download MP4 · SRT captions · Use the video controls for captions and fullscreen; Escape returns to this lesson.

About this recording

Actual moving PAS saved offline-site inspection, plus separately labelled historical live configuration/log uploads recorded on 7 November 2026. No new configuration write, memory clearing, or Event Log report demonstration. The portrait Short retains full PAS above a same-time detail view.

Michael (Australian) narration from ElevenLabs. Edited PAS screen recording.

The EM133-XM provides different records for different questions. Start with the question you need the history to answer, then inspect the file's configuration and uploaded contents.

Australian narrated walkthrough with written guidance.

Before you start

Compare the files before choosing a report

The XM-specific file table lists Data Logs 1, 2 and 3 alongside the Event Log and Data Log 16. The number in a log name identifies a destination; it does not define an application's measurement purpose.

FileWhat it recordsWhat to inspect
Data Log 1Selected measured parameters when its configured trigger records them.Parameter list, units, trigger, action and retention.
Data Log 2A separately configurable conventional parameter file on XM.Its own parameter list and actual trigger destination.
Data Log 3Another separately configurable conventional parameter file on XM.Its own purpose, trigger and record capacity.
Data Log 16Daily Billing/TOU energy and maximum-demand profile sections, as enabled.Billing sources, profile flags, tariffs, clock and available sections.
Event LogTime-tagged configuration changes, resets and device diagnostics.Time, cause/source, effect and the surrounding sequence.

Source 1 · Source 3 · Source 4

Separate contents, trigger and allocation

A conventional recorder has three separate design decisions: which quantities appear in each record, when the recording action occurs, and how much history its allocation can retain.

Changing a file name or selecting a log in PAS does not start recording. An allocated but untriggered file can remain empty. A working trigger with the wrong destination can place records in a different file.

The XM datasheet specifies up to 16 parameters/channels for interval recording. Think of those as columns within each timestamped record. Retained days depend on each file’s record capacity and how often records are added, including any event-triggered additions. Confirm the actual allocation before estimating retention.

Source 2 · Source 1 · Source 6 · Source 7

Follow the PAS menu route

Use the menu workflow first. Keep PAS maximised, the full Site Tree and clock visible, and expand the selected site with + where needed. Read the selected log number aloud before each comparison; move the cursor beside the fields when pausing to explain them.

  1. Compare Data Logs 1, 2 and 3

    Open MeterSetup > Memory/Log > Data Recorder. Select Log No. 1 and read its name and populated Group/Parameter rows. Change to Log No. 2, then Log No. 3, pausing to show the selected number and each file’s contents. A saved offline site is a configuration example, not current meter readback.

    Source 2 · Source 1

  2. Connect contents to memory allocation

    Select Log Memory. Locate the corresponding Data Log 1, 2 and 3 rows and compare file type, Number of Records, parameter count and reported size. Inspect the partition properties without applying changes. The number of values in a record and the number of records retained are different settings.

    Source 6 · Source 1 · Source 7

  3. Open historical records

    Use Logs > Upload Logs for a connected upload. To inspect a saved archive, use File > Open, select Access Database (*.mdb), choose the database and the intended table, then Open.

    Source 5

Source 6 · Source 2 · Source 5

Find the trigger, action and parameter lists

Keep the manual beside PAS. Near the end of the EM13x Installation and Operation Manual, Appendix D lists Setpoint Triggers and Actions: Table 25 begins at printed page 169 (PDF page 172), and Table 26 is at printed page 172 (PDF page 175). Use these to distinguish the condition that starts an action from the action itself.

Appendix E, Parameters for Data Monitoring and Logging, starts at printed page 173 (PDF page 176). Table 27 pairs PAS abbreviations with their meanings and groups. Find the Group first, then the Parameter; check units and whether the quantity is instantaneous, demand or accumulated energy.

Return to MeterSetup > General Setup > Control/Alarm Setpoints to inspect the trigger and destination, then MeterSetup > Memory/Log > Data Recorder to inspect recorded fields. The older family action list does not enumerate every XM destination, so compare it with the selected model’s actual PAS choices.

Source 8

Give separate files a clear application purpose

ILLUSTRATIVE design: one conventional file could hold energy-related quantities, another voltage/current trends and another a condition-focused set of parameters. These are teaching examples, not factory-assigned roles or claims about the current demo setup.

Separate files can keep different parameter selections and recording needs understandable. They still share the meter's finite memory, so calculate retention for every active file and include any additional event-triggered records.

Source 1 · Source 2 · Source 6

Treat the archive as the evidence

Record settings explain what was intended. Uploaded rows show what was retained. Check both before concluding that a logging arrangement works.

Verify each required file, time range, field names, units and continuity. A daily profile does not replace a short-interval log; an Event Log does not replace measured-value history. Preserve all required records before clearing or repartitioning.

Source 5 · Source 3 · Source 4 · Source 6

Limits and checks

Check your understanding

Are Data Logs 1, 2 and 3 permanently assigned to energy, voltage and alarms?

Show answer

No. Their conventional parameter lists are separately configurable. Any suggested division is an application design, not a fixed factory role.

Source 1 · Source 2

Does an allocated log prove that records are being generated?

Show answer

No. Verify its trigger and destination, then upload and inspect actual records.

Source 1 · Source 5

Which file helps investigate configuration changes?

Show answer

The Event Log provides time-tagged configuration/reset/diagnostic history; compare it with relevant data logs where needed.

Source 4

Sources

Revision and review details
RevisionChange and reasonReview / supersedes
20261108-video-v4
8 November 2026
Revised teaching video, captions and chapter timing.

Show the menu and relevant setup screens clearly, with spoken guidance and pauses.

Final export checked before development deployment.

20261108-retention-v2

20261108-draft-v1
8 November 2026
Added a detailed model-scoped log lesson with source references and learner checks.

Explain each log's purpose, PAS controls and interpretation without assigning invented factory roles.

Manufacturer source review complete; independent verification pending.

None

20261108-draft-v2
8 November 2026
Added the narrated log tour, revised portrait Short, captions and measured chapter navigation.

Connect the source-checked lessons to actual saved-site PAS views and reusable feature content.

Independent technical/documentary checks passed for the selected media; Gemini feedback adjudicated. Human editorial acceptance remains pending.

20261108-draft-v1

20261108-retention-v2
8 November 2026
Clarified parameters per record, per-file allocation and retention; added sequential log navigation and manual-reference guidance where relevant.

Connect the displayed recorder settings with practical memory planning.

Manufacturer-source review completed; no new footage or live changes claimed.

20261108-draft-v2