EXPERTPOWER · DASHBOARDS AND DATES
Dashboards, dates and viewing your data
Find the meter, use Detailed View and choose an explicit period before interpreting its charts.
Jump to a topic
About this recording
Genuine browser actions in the Manager interface, edited to remove preparation waits. Emma narration from ElevenLabs. Customer, site and device names are temporary presentation masks; the recorded measurements are unchanged. Cost panels are masked. Billing is a separate lesson.
Use fullscreen for small labels, captions, pause and rewind. Interface options can vary with access and device. This lesson changes viewing controls only.
1. Choose the intended meter
In Manager, expand the Device Tree customer and site branches, then select the meter. Read the customer, site and device in Current Selection. Clicking a selected meter toggles it off; if No selection appears, select it again. Collapsing a branch leaves the selection in place.
2. Open a populated dashboard
Use Dashboard → Analysis → Detailed View. Check the breadcrumb. Begin with Max Demand KW and Energy Details, then scroll to Load Profile and Weekly Distribution. Availability depends on your access, the device and its data. No data to display does not establish a fault or zero consumption.
3. Set and confirm the dates
Open the green date range. Use Pick Month for a named month, checking year and month. The recorded October example runs from 1 October at midnight to 1 November at midnight. Apply updates the range and leaves the panel open; Apply & Close applies it and closes the panel. Check the final range on the loaded dashboard. Typed slash dates were ambiguous in this session: verify the resulting calendar and range.
4. Inspect a shorter period
Pick Day offers year, month and numbered-day controls. Check both From and To dates and times. The recorded day runs from 7 October at midnight to 8 October at midnight. Check the new range after applying it. Use comparable windows when comparing results.
5. Choose the display resolution
The date range defines the window. The neighbouring resolution control groups its display. Read the resulting axes after choosing 30 Min., Hours, Days, Weeks or Months. The date arrows move the active period; check the resulting endpoints rather than assuming a fixed one-day step.
6. Check the legend and filters
Read quantity labels and units before comparing colours. Clicking a legend entry hides or restores the series; it does not delete records. Hover for a point’s date, quantity and value, then move the pointer clear. Return the weekday filter to All Days when you need the full selected period.
7. Use the profile and distribution together
Load Profile shows the available power quantities and power factor against their own axes. Weekly Distribution groups displayed values by weekday and time. Heatmap and sensitivity change the shading while leaving the displayed values unchanged in this example. A dash is not a measured zero. A pattern alone does not identify its cause.
8. Check the source records
Use Readings → Data Logs, then the Datalogs list. Check the actual parameter columns and timestamp spacing. The example includes both midnight boundaries. A row count alone does not establish complete coverage, and dashboard resolution does not prove the meter’s recording interval.
Transcript and references
This Expertpower walkthrough shows how to find a meter, choose a useful dashboard, set the dates and read the resulting charts. We will use Detailed View as our main example, then look more closely at a recorded data view. Billing is covered separately. Customer, site and device names have been masked for this recording. The measurements themselves have not been replaced.
Start by checking that you are in Manager. The menus across the top choose what you want to see. The Device Tree on the left chooses whose data you are looking at. These are two different decisions: first the view, then the device. Open the Device Tree and use the plus beside the customer to expand its sites. Expand the required site to reveal the meter. A minus collapses a branch again. Collapsing a branch does not itself clear the selected meter.
Click the meter name to select it. Check the green row and, above the tree, Current Selection. Read the customer, site and device together. Selecting a similar-looking name at a different site can give you a perfectly valid chart for the wrong meter. In this interface, clicking an already selected meter toggles it off. If you see No selection, choose the required meter again. Before investigating any unusual result, confirm the selection first.
The ordinary menu route is Dashboard, then Analysis, then Detailed View. The breadcrumb at the top confirms the page you reached. The names and options you see may depend on your access and the selected device. Use the actual menu available in your account rather than assuming every dashboard will look identical.
Detailed View brings several useful displays together. At the top we can see a maximum-demand value and the time associated with it. Below, Energy Details plots the selected quantities over the chosen range. Further down are the Load Profile and Weekly Distribution. We will use these populated panels through the walkthrough. A tile marked No data to display does not, by itself, tell you why the information is absent. Check the device, dates and relevant source data before treating that tile as evidence of a fault. Cost panels are masked here because this overview is about viewing measurements.
Before reading a number, check three things: the selected meter, the dates at the top and the quantity and units in the panel. A demand value in kilowatts answers a different question from accumulated energy in kilowatt-hours. Also look at the timestamp. A maximum found within an earlier date range is historical information; it is not a claim about what the meter is drawing now. Keep those checks together as you move between views.
Click the green date range at the top to open Date selection. The panel contains quick choices and separate From and To controls. You can see shortcuts such as Today, Past Week and Past Month, as well as Pick Day, Pick Month, Pick Quarter and Pick Year. A quick preset and a named calendar month are different ways to choose the period. Check their endpoints. Choose the one that matches the question you are answering.
For a complete named month, use Pick Month. Choose the year, then the month. In our October example, the controls show the first of October at midnight through to the first of November at midnight. Read both endpoints before applying them. The ending boundary is the start of the following month, rather than a guessed late-evening time on the last day.
Apply updates the selection while keeping the panel available. Apply and Close updates it and returns you to the dashboard. After the panel closes, check the green range again and let the charts finish loading. That final check matters: an edited field or a highlighted calendar cell is only an intermediate step. The range shown on the loaded dashboard is the context you will use to interpret its results.
For this recording we use the calendar controls. During preparation, typing a slash-formatted date was interpreted differently from the displayed format in this session. If you type dates in your own account, verify the calendar and final range before relying on them. Do not assume that the way you entered a date proves how the application understood it.
A month is useful for an overview, but it can hide the shape of an individual day. Open Date selection again and choose Pick Day. Pick Day provides year, month and numbered-day controls. Choose the required year and month before choosing the day. The From and To calendars below show the resulting boundaries. The same day number appears in every month, so check the headings as well as the number.
Use a short, known period when you want to inspect a particular pattern. In this example we choose a day within the recorded month and the following midnight as the end. The time controls beside the calendars let you see the exact start and end times. Leave them at midnight for a complete-day example. For a partial-day question, choose the required times and check both boundaries before applying the range.
The point is to make the period explicit. A comparison between two screenshots is difficult to interpret if one covers a whole day and the other covers only part of it. A low total can reflect a shorter window rather than a change in the load. Similarly, a partial current day should not be compared casually with a completed day.
Apply and Close, confirm the resulting date range and wait for the requested view to load. If the new display is empty, first check the selection and period. Do not turn an empty result into a claim of zero consumption. Once you have inspected the shorter period, you can return to a month using the same calendar controls. The meter selection and the date range are checks you repeat whenever the question changes.
The date range chooses the overall window. The adjacent resolution control chooses how the dashboard groups the display. Those controls work together, but they do different jobs. Open the resolution menu to see the available choices. In this view they include thirty minutes, Hours, Days, Weeks and Months.
For a monthly overview, Days makes it easier to compare one day with the next. Weeks reduces the number of plotted groups and helps you see a broader pattern. A shorter resolution can reveal detail that disappears when values are grouped over a longer period. A longer resolution can make an extended period easier to scan. Choose a scale that answers the question, then read the labels on the resulting chart. Do not interpret a weekly bar as if it were a single day's result.
The arrows beside the date range move the displayed period backwards or forwards. Watch the range change when you use them; do not assume that an arrow always means one calendar day. Its useful meaning comes from the active period and the resulting dates. After moving, let the dashboard update and check that the meter has remained the one you intended.
A practical routine is to begin broadly, identify the period of interest, then narrow the dates and resolution. Keep a note of the range and units with any screenshot you retain. When comparing two views, use comparable periods and grouping. The screen may offer a wide range of choices, but more plotted points do not automatically make the answer clearer. Select the amount of detail that lets you see the pattern you are trying to understand.
Return to the populated Energy Details chart. Begin with its axes and legend. The horizontal axis shows the time groups. The legend names the plotted quantities and includes their units. In this example you can see import and export energy, demand and other available quantities. Several series may be present together, so colour alone is not enough to identify a measurement. Match the colour to its label.
Clicking a legend entry shows or hides that series in the chart. A greyed entry indicates that it is not currently displayed. Use this to reduce clutter while comparing a small set of quantities, and turn the series back on when you need it. Hiding a series changes the presentation; it does not delete the meter's records. A line or bar that disappears after a legend click should not be described as missing data.
Move the pointer over a plotted point to inspect its tooltip. Read the date or time and the quantity together with the value. Then move the pointer clear so the chart is visible again. A tooltip is useful for a specific point; the wider chart is useful for the surrounding pattern. Neither view should lose its time and unit context.
The All Days control also offers individual weekdays in this view. This can help you focus on a recurring part of the week. Check that filter when a chart seems to contain fewer days than expected, and return to All Days for the complete selected period. A filter, a hidden series and a genuinely absent record are different explanations for something not appearing. Check the display controls before drawing a conclusion about the underlying measurements.
Scroll down to Load Profile. This chart shows how the available power quantities vary through the selected period. Read the legend before interpreting a trace: active power, apparent power, reactive power and power factor are separate quantities. Notice that the axes can have different units and scales. A power-factor trace should not be read against a power axis.
Use the same broad-to-narrow approach here. A month lets you see repeating daily patterns. A shorter range helps you inspect the timing of a change. The graph can show an observation worth investigating, but a peak or a negative value does not identify its cause on its own. Keep the selected record, dates and quantity with the observation, then check the appropriate source view before diagnosing the installation.
Further down, Weekly Distribution arranges the displayed values by weekday and time of day. The colour shading helps you find patterns across that table. Read a row and column together rather than treating the colour as a complete answer. A dash is not a measured zero. If a cell or period needs investigation, return to a narrower dated view and inspect the relevant records.
The sensitivity and heatmap controls change how this table is presented. They can help you see a pattern, but changing the colour treatment does not change the measurements. Keep the actual values, labels and chosen range in view. This is a useful starting point for asking when something happens. Establishing why it happens requires the appropriate data and evidence beyond the dashboard.
For a closer look at what the meter recorded, use Readings, then Data Logs. Confirm the meter again and choose the available log from the Datalogs list. The selected log determines the columns and quantities you see. Data Log 1 in this demonstration contains its own recorded parameters; do not assume another meter will have the same list.
Use a short date range, then compare the graph with the timestamped Details table. Read the spacing between the actual timestamps before describing the recording interval. This view includes a record at each midnight boundary, so check the first and last timestamps rather than assuming a row count proves a complete day. A dashboard resolution is a display choice; it does not by itself prove how the meter's log was configured. We will work through interval records in a separate lesson.
Return to Detailed View when you want the dashboard context again. The checks remain the same: the correct customer, site and device; the required From and To boundaries; the displayed resolution; and the active series or weekday filter. Use the ordinary menu route first, then use the tree and display controls to refine the view.
You can now navigate to a populated dashboard, choose an explicit period and inspect its charts without changing customer configuration. The chapters let you return directly to each task. The shorter lessons will take these steps one at a time. Billing will follow in a separate walkthrough, using the checked Network Operations procedures.
References
- Expertpower user manual — SATEC Australia — general navigation and date selection; interface versions differ.
- Expertpower software and documentation — SATEC Australia
Current screen behaviour was checked in the recorded EU Manager session on 9 November 2026. The supplied Operation Manual, Administrator Menu and Reports manual were used as local references; administrative and billing actions are outside this overview.