EM132 · DATASHEET

EM132 multi-function meter datasheet

Multi-function power meter and smart transducer.

Transcribed from the SATEC Australia datasheet TBV1.0, 21 September 2026 (PDF, 9 pages, 1071 KB). If this page and the PDF differ, the PDF is right; tell us through the contact form.

Overview

SATEC EM132 is a multi-function power meter, ideal for a wide range of applications such as energy management metering, industrial power monitoring and interfacing SCADA in utility substations. Based on SATEC’s PM13X family functionality, the EM132 is designed as a DIN-rail mount device equipped with a built-in communication port and an anti-tamper enclosure.

As a smart transducer, the EM132 provides four analogue outputs for selectable power parameters, together with load-shedding and alerting of irregularities, and supports a modular I/O system with up to 16 digital and analogue points. Broad-range frequency measurement from 25Hz to 400Hz and a choice of built-in and optional communication ports make it equally suited to retrofit and new-build metering projects.

EM132: Standard model with a single built-in RS-485 communication port.

EM132-TP: Includes a second built-in RS-485 port (AC/DC power supply model only).

Main features

Feature capabilities

Applications

  • Energy management metering
  • Industrial power monitoring
  • SCADA interfacing in utility substations
  • Retrofit and new-build sub-metering, including with SATEC HACS current sensors

Multi-functional 3-phase smart meter

  • True RMS volts, amps, power, power factor, neutral current, angles and unbalance for voltage and current, frequency, symmetrical components and many more
  • Ampere/volt demand meter
  • 25, 50, 60 and 400Hz measurements
  • 128 samples per cycle

Energy meter

  • Accuracy Class 0.5S per AS/IEC 62053-22 / ANSI
  • Four-quadrant active and reactive energy polyphase static meter
  • Three-phase total and per-phase energy measurements: active, reactive and apparent energy counters
  • Automatic logging of daily energy and maximum demand profiles

Real-time waveform capture (via PC)

  • Real-time “scope mode” waveform monitoring via PAS software.

Programmable logical controller

  • Embedded programmable controller
  • 16 control set points; programmable thresholds and delays
  • Relay output control
  • 1-cycle response time

Event and data recording

  • Non-volatile memory for timestamped event and data recording: over 90 days of half-hourly writing of 4 parameters, recording more than 200 events over the entire period
  • Event recorder for logging internal diagnostic events and setup changes
  • Two data recorders; programmable data logs on a periodic basis; automatic daily energy log and maximum demand profile

Voltage inputs

  • Direct measurement 0–690V AC.

Current input options

  • 1A or 5A inputs from CT secondary
  • 40mA input designed for SATEC HACS CTs (100–3,000A options)
  • 63A or 100A direct connection
  • RS: unique input for 5A-rated split-core HACS CTs, ideal for retrofit installation

Digital and analogue I/O

  • Built-in: 2 digital inputs and 1 form-A SSR output
  • 4DIO module: 4 digital inputs, 2 relay outputs (SSR or EM relay)
  • 12DIO module: 12 digital inputs, 4 relay outputs (with optional Ethernet or RS-485 port)
  • 4AO, 8DI and 2AI modules also available

Communication — ports and protocols

  • On-board: standard 2-wire RS-485; optional second built-in RS-485 port
  • Optional interfaces: RS-232/422/485, 10/100BaseT Ethernet, Profibus, 4G cellular modem
  • Protocols: Modbus RTU, SATEC ASCII, DNP 3.0, IEC 60870-5-101/104 (optional)

Display

  • 2×16 character LCD display; adjustable update time
  • Auto-scroll option; auto-return to a default page

Meter security

  • 3-level password access to meter setups and data.

Software support and firmware

  • Includes comprehensive Power Analysis Software (PAS) for configuration and data acquisition
  • Compatible with SATEC’s Expertpower web-based energy management platform (subscription)
  • Connect via the eXpertConnect™ App for on-the-go readings and diagnostics
  • Any third-party software supporting the open protocol
  • Easy firmware upgrading via serial or Ethernet ports

Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.

Specifications

Voltage inputs
Installation categoryCategory III
Over-voltage withstand1,000V AC continuous, 2,000V AC for 1 second
Input impedance1 MΩ
Wire sizeUp to 12 AWG (up to 2.5mm²)
Model with aux. power supply
Nominal voltage400/690V AC (L-N/L-L)
Measurement range15–480/828V AC (L-N/L-L)
Frequency range25–400 Hz
Burden for 400V< 0.4 VA
Burden for 120V< 0.04 VA
Model self-energised from voltage inputs*
Nominal voltage (HACS, 1A/5A/RS5 models)120/207V AC to 230/400V AC (L-N/L-L); 120/207V AC to 277/480V AC (L-N/L-L)
Frequency range50/60 Hz
Burden for 277V< 1.5 VA
Burden for 120V< 2 VA

* Not available with the EM132-TP model.

Current inputs
Current connections3 galvanically isolated inputs
Current ratings../5A CT; ../1A CT; direct up to 63A**; remote CT (40mA)
Starting current0.2% In
Burden per phase<0.2 VA (../5A); <0.05 VA (../1A)
Overload (continuous)2×In (1.2×In for 100A model)
Over current50×In for 1 second
Galvanic isolation4,000V AC (L-G) for 1 min.
Terminal blocks6 sealed, pitch 7–10mm, 4 to 16 mm²

** Connecting up to 100A is possible under certain conditions (up to 55°C ambient temperature).

Auxiliary power supply
Rated input57.7–277V AC; 48–290V DC
Tolerance@V AC = ±15%; @V DC = ±10%
Insulation dielectric withstand4,000V AC for 1 min.
Burden5VA
Terminal blocks2 sealed, pitch 7–10mm, 2.5 to 4mm²
Optional power supply
Rated input12–24V DC
Tolerance±20%
Optional modular I/O – electromechanical relay
Dry contact1 contact (SPST Form A)
Rating5A/250V AC; 5A/30V DC
Galvanic isolationContacts–coil: 3,000V AC 1 min; open contacts: 750V AC
Operate time10 ms max
Release time5 ms max
Update time1 cycle
Wire size14 AWG (up to 1.5 mm²)
Optional modular I/O – solid state relay
Dry contact1 contact (SPST Form A)
Rating0.15A/250V AC/DC
Galvanic isolation3,750V AC 1 min
Operate time1 ms max
Release time0.25 ms max
Update time1 cycle
Connector / wire sizeRemovable, 4 pins; 14 AWG (up to 1.5 mm²)
Optional modular I/O – digital inputs
Dry / wet contactsInternally wetted @ 24V DC, or wet contact @ 250V DC (12DI/4DO only)
SensitivityOpen >100kΩ; closed <100Ω
Galvanic isolation3,750V AC 1 min
Internal power supply24V DC, 4DI/2DO or 12DI/4DO
External power supply250V DC (12DI/4DO only)
Scan time1 ms
Connector / wire sizeRemovable, 5 pins; 14 AWG (up to 1.5 mm²)
Optional modular I/O – analogue outputs
Ranges (upon order)±1mA / 0–1mA (max. 5kΩ, 100% overload); 0–20mA / 4–20mA (max. 510Ω)
Isolation2,500V AC 1 min
Power supplyInternal
Accuracy0.5% FS
Update time1 cycle
Connector / wire sizeRemovable, 5 pins; 14 AWG (up to 1.5 mm²)
Built-in communication – serial (RS-485)
Max. baud rate115.2 kb/s
Optical isolation3,000V AC (L-G) for 1 min.
Max. cable length1,000 m
ProtocolsModbus RTU/ASCII; DNP 3.0; IEC 60870-5-101 (option)
Terminal blocks3 sealed, pitch 7–10mm, 2.5 to 4 mm²
COM2 (optional module) – Ethernet port
AvailabilityIndependent module or add-on to 12DIOR module; plug-in DIN-rail mount 73×90×32mm, or plug-in no-mount
InterfaceTransformer-isolated 10/100BaseT Ethernet
Supported protocolsModbus/TCP (port 502), IEC 60870-5-104, DNP3/TCP (port 20000)
Simultaneous connections4 (2 Modbus/TCP + 2 DNP3/TCP)
Connector typeRJ45 modular
Isolation1,500V DC @ 1 min
Cellular port
Supported protocolsModbus/TCP (port 502), DNP3/TCP (port 20000)
Connector typeSMA
Profibus DP (IEC 61158)
InterfaceRS-485 optically isolated Profibus
Connector typeRemovable, 5 pins
Baud rate9,600 bit/s – 12 Mbit/s (auto-detect)
Data32 bytes input, 32 bytes output; PROFIBUS DP
RS-232/422-485 port
InterfaceRS-232 or RS-422/485, optically isolated
Isolation3,000V AC 1 min
Baud rateUp to 115.2 kbps
Supported protocolsModbus RTU, DNP3, SATEC ASCII, IEC 60870-5-101
Connector typeRemovable 5-pin (RS-422/485); DB9 (RS-232)
Front panel
Display type2×16 character transflective LCD with backlight
Character size3.2×1.85 mm
Viewing area46×11 mm
LEDs6 total: 1 pulse calibration output, 3 voltage indication, 2 RX/TX activity
NameplateAccording to IEC 60688 & IEC 62052-11
Construction
EnclosureDIN-rail mount, complies with EN50022
Dimensions [W×H×D]125 × 90 × 75mm
Enclosure materialReinforced polycarbonate
Enclosure protectionIP20
Environmental conditions
Operational−25°C to 60°C (−13°F to 140°F)
Storage−30°C to 85°C (−22°F to 185°F)

Standards compliance

EMC immunity (IEC 60688 and IEC 62052-11)

  • IEC 61000-4-2: Electrostatic discharge, 15/8kV air/contact
  • IEC 61000-4-3: Electromagnetic RF fields, 10V/m @ 80MHz–1000MHz
  • IEC 61000-4-4: Fast transients burst, 4kV on current and voltage circuits, 2kV for auxiliary circuits
  • IEC 61000-4-5: Surge, 4kV on current and voltage circuits, 1kV for auxiliary circuits
  • IEC 61000-4-6: Conducted radio-frequency, 10V @ 0.15MHz–80MHz
  • IEC 61000-4-8: Power frequency magnetic field

EMC emission (radiated / conducted)

  • EN 55022:2010 Class A (CISPR 22)
  • FCC Part 15 Class A (mandatory)

Safety

  • UL / IEC 61010-1
  • UL 916

Insulation

  • IEC 62052-11: Insulation impulse 6kV/500Ω @ 1.2/50 µs
  • AS/IEC 62053-22: AC voltage tests related to ground, 4kV AC @ 1 min, for power and signal ports (above 40V)
  • 2.5kV AC r.m.s. @ 1 min, for other ports (below 40V)

Accuracy according to

  • AS/IEC 62053-22, Class 0.5S – active energy
  • IEC 62053-21, Class 0.5 – reactive energy
  • IEC 60688, Class 0.5S – active energy
  • IEC 60688, Class 1 – reactive energy
  • ANSI C12.20, Class 0.5

Ordering information

MODEL – CURRENT – CAL. FREQ. – RES. – POWER – SEAL – PROTOCOL

Models
EM132: Multi-function transducerEM132
EM132-TP: EM132 with two integral RS-485 ports (AC/DC power supply only)EM132-TP
Current inputs
5 Ampere5
1 Ampere1
Direct current measurement up to 63A*63
Direct current measurement up to 100A* (up to 55°C ambient)100
5A split-core remote High Accuracy Current Sensor (HACS)*RS5
High Accuracy Current Sensors (HACS)**HACS
High Accuracy Current Sensors (HACS), with wiresHACS-SPDR
Calibration at frequency
25 Hz (supports 1A and 5A models only)25HZ
50 Hz50HZ
60 Hz60HZ
400 Hz (supports 1A and 5A models only)400HZ
Resolution
Low resolution 1A, 1V–
High resolution 0.01A, 0.1VH
Power supply
40–300V AC/DCACDC
Self-energised: powered from measured voltages (120–277V L-N), 50/60Hz models only. Not suitable for EM132-TPSE
12V/24V DC power supply. Not suitable for EM132-TP21DC
Mechanical seal
Standard seal–
Special sealS
Electronic seal
Energy register is accessible–
Energy register is protectedP
Communication protocol
Modbus and DNP 3.0–
Modbus and IEC 60870-5-101/104***870

Order-code bar condensed for width — mechanical and electronic seal are two separate code positions; see the tables for the full breakdown. * For 50/60Hz only. ** For 50/60Hz only, requires ordering of 3 HACS. *** –104 requires ETH; not compatible with AR version, does not work over cellular network.

Expansion modules

Maximum 1 module per instrument, can be ordered separately.

Analogue outputs
4 analogue outputs: ±1mAAO1
4 analogue outputs: 0–20mAAO2
4 analogue outputs: 0–1mAAO3
4 analogue outputs: 4–20mAAO4
4 analogue outputs: 0–5mAAO7
4 analogue outputs: ±5mAAO8
Communication
Ethernet (TCP/IP) for DIN railETHD
ProfibusPRO
RS232 (for DIN rail enclosure)RS232D
RS232/422/485RS232
CAT-M / LTE modem – x: G=Europe, V=Verizon (US), A=AT&T (US), T=Telstra (AUS); y: T=Top Antenna, F=Front Antenna*LTEx-y

* Does not support 870 protocol. Supplied with bendable antenna.

Digital inputs
4 DI (dry contact) / 2 relay outputs, 250V/5A ACDIOR
4 DI (dry contact) / 2 SSR outputs, 250V/0.1A ACDIOS
8 DI (dry contact)8DI
12 DIOR module
12 digital inputs / 4 relay outputs, 250V/5A AC12DIOR
Digital input rating – dry contact (DRC), 48V, 125V or 250VDRC/48V/125V/250V
Communication port: none–
Communication port: RS-485485
Communication port: EthernetETH

Downloads and related

Questions about this datasheet? Use the contact form.