SATEC’s recent release of the PRO series of energy and power quality metering, brings together current technology for a compact design for an all in powerful effective line of power meters for advanced power applications, including waveform recording and AC/DC power metering.
The compact DIN PRO Series Power Quality Meter is available as five (5) DIN design, the EM235 DIN-rail form factor design. With an advanced communication platform including IEC 61850, DNP3 and Dual Port Ethernet this series provides the ultimate solution for the digital substation, industrial, commercial energy management and renewable energy platforms. The design takes into account formats for Frequency Control Ancillary Services (FCAS) applications.
The SATEC PRO EM235 provides Accuracy performance Class 0.2S with 256 samples per cycle calculation with standard features such as:
- Memory: 16 GB on-board
- Modbus Master
- Accuracy Class 0.2S per AS/IEC 62053-22
- PMD measurement standards IEC 61557-12
- Harmonics up to 63rd
- Input 5A or 1A CT
- HACS/CT Input
- Real Time Clock (RTC)
- Dual Ethernet (redundancy/daisy-chain)
- USB (type C)
- RS-485
- Modbus
- DNP 3
- Two (2) Digital Inputs
- One (1) Solid State Relay Output
- One (1) Analogue Input
- Power Quality: Waveform Capture and event recording
- Neutral Current Metering
- Compact DIN design
- User Friendly HMI
Options:
- Add on I/O expansion modules
- IEC 61850 with MMS & Goose messaging
- DC Applications up to 3000VDC
- Backup Power Supply
Please refer to our EM235 DIN PRO Series datasheet for further information or contact us to discuss.
Explore related topics:
For Your Industry
- Why Power Visibility Is the First Step to Unlocking Data Centre Stranded Capacity
- Power Quality Monitoring for Pharmaceutical Sites: What Should You Measure?
- Electric Truck Charging: Why Depot Metering Is The Key To Managing New Power Demand
Standards & Compliance
- What Does an EN50160 Power Quality Report Actually Tell You?
- How A Power Quality Recorder Helps Identify The Root Cause Of Voltage Disturbances
- Why Real-Time Power Quality Monitoring Matters for Harmonic Distortion
Related Reading
- Waveform Data In Power Quality Monitoring: What Facilities Teams Should Track
- How Check Metering Can Reveal Hidden Load Issues and Power Anomalies
- What Is A Power Energy Data Logger And When Should You Use One?
Trending in Your Sector
- Phase Rotation Errors in Multi-Board Sites: How Fixing It “Over Here” Can Break It “Over There”
- Understanding the Difference with IEC 61000-4-30 Between Class A and Class S
Trending Outside Your Sector