+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • RESOURCES
  • CONTACT
NextPrevious
Building Management Systems & Energy Management

Programmable Logic Controller (PLC) – A Meter for Engineers & Automation Professionals

By SATEC (Australia) Pty Ltd | Featured, Industry News | Comments are Closed | 18 September, 2019 | 2

Programmable Logic Controller (PLC), Building Management Systems (BMS) and SCADA generally perform most metering measurement and monitoring solutions. The rise of Energy Management Systems (EMS) is improving electrical metering systems due to several factors, particularly since electrical measurements and monitoring applications can be so vast in their respective applications.

There is a significant difference between low cost metering solutions and advanced smart meters. Subsequently, there is a wide gap between how more advanced solutions can serve applications best instead of traditional low cost metering implementations.

With a PLC with the meter, the concept of Distributed Logic can be realised. Localised control is possible with simple use of programming software, instructing the meter to perform a wide range of tasks usually done by traditional methods.
Examples of such applications are: Demand Response, Demand-Side-Participation billing applications, Fast-Demand-Management, Enhanced Diagnostics, Auto-Load-Shedding, Change-of-State Notifications, Pulse Counting (water, gas, thermal metering), Phase Failure/Reversal Relay, etc.

The Technical Details

Through use of the embedded Programmable Logic Controller, Distributed Logic can be achieved enhancing control systems by improving communications bandwidth. Instead of a traditional ‘polling’ structure, the SATEC meters can send messages to BMS or SCADA on event driven applications.

This concept can also lessen the burden on scan-time, improving code efficiency and effectiveness. SATEC’s embedded PLC operates in a single-cycle, giving applications 20ms throughput @ 50HZ. Therefore, improved monitoring of assets is assured.
Demand Response applications are served best by various approaches. First, the meter can send messages to the control system when ‘Demand Thresholds’ have been met, or a triggered parameter is observed by the meter. Another approach is for the meter to perform an operation of a relay, to isolate and operate a respective load such as a pump or fan.

Data communication efficiency is also achieved within the meters. A ‘block transfer’ of 120x communication-registers in a ‘single-scan’ significantly improves control system throughput ability. Traditionally, ‘multiple-scans’ are performed by BMS/SCADA whereby SATEC meters allow for improved communication solutions.

16-Bit Scaled Data is provided to ½ data packet transmission size. However, 32-Bit structured data can also be obtained from the meters, which is more commonly used. The key point is that SATEC meters can provide more effective, efficient and lower bandwidth communication techniques with training and awareness of such features and benefits.

In summary, extensive applications can be achieved using these automation & control philosophies. The true benefit of a smart meter can be understood and achieved. Smarter than your average meter, the SATEC Embedded PLC is the choice for Engineers, Automation and Metering Professionals.

Contact SATEC to discuss your energy management needs.

BMS, building management, energy management, energy management systems, PLC, programmable logic controller

NextPrevious

BOOK AN ONLINE MEETING


INDUSTRY NEWS & VIEWS

Get fortnightly updates delivered straight to your inbox.

Energy Management Knowledge Base

NEWS

  • Battery Round-Trip Efficiency Explained: Where Stored Energy Is Lost
  • Secondary Settlement Points Explained: How Flexible Energy Trading Is Changing In Australia
  • How Energy Metering Can Reduce The Cost Of Wastewater Treatment
  • Three Phase EV Charging and Load Management: How to Avoid Overloading Your Site
  • Power Factor Correction for VFD Loads: Why Capacitor Banks May Not Solve the Real Problem
SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Energy Management Knowledge Base
  • Terms & Conditions
  • Privacy Policy
  • Privacy Policy – eXpertConnect

Recent Posts

  • Battery Round-Trip Efficiency Explained Where Stored Energy Is Lost

    Battery Round-Trip Efficiency Explained: Where Stored Energy Is Lost

    Learn how battery round-trip efficiency is calculated, where energy is lost and how accurate SATEC metering supports BESS performance analysis in Australia.

    23 July, 2026
  • Secondary Settlement Points Explained How Flexible Energy Trading Is Changing In Australia

    Secondary Settlement Points Explained: How Flexible Energy Trading Is Changing In Australia

    Learn how secondary settlement points could enable flexible energy trading, separate resource metering and greater provider choice in Australia.

    22 July, 2026
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • RESOURCES
  • CONTACT
SATEC (Australia) Pty Ltd