+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • About SATEC
  • HARDWARE
    • Phasor Measurement Unit
    • Power Quality Analysers
    • NMI Approved Energy Meters
    • Multi-Channel Energy Meters
    • Current Transformers
    • Expansion Modules
    • All Metering Products
  • SOFTWARE
    • Power Analysis Software (PAS)
    • eXpertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
  • SOLUTIONS
    • Power of Choice Metering
    • NMI Approved Retrofit Energy Metering
    • Frequency Control Ancillary Services (FCAS)
    • Disturbance Direction Detection
    • Phasor Measurement Unit
    • Automatic Demand Response
    • Large-Scale Generation Certificates (LGCs)
  • NEWS
  • DOWNLOADS
    • Manuals & Datasheets
    • Billing & Revenue Metering Catalogue
    • Power Analysis Software (PAS)
    • Current Product Catalogue
  • CONTACT
NextPrevious
PM180 Power Quality Analyser

Power Quality Analyser with Disturbance Direction Detection

By SATEC (Australia) Pty Ltd | Featured, Industry News | Comments are Closed | 9 September, 2021 | 2

SATEC has added further enhancements and advanced features for power quality monitoring with the PM180. The latest release incorporates disturbance direction detection and analysis, allowing identification and location of voltage sags or voltage swells, relative to the monitoring location. The PM180 Power Quality Analyser is a Class A device for PQ metering.

Damage Resulting and Disturbances PQ Network

Detecting network disturbances, such as voltage sags/dips and swells, is an important aspect of power quality monitoring. However, it is often difficult to determine and locate the cause responsible for the disturbance detected. This of course presents a further challenge in preventing such future events.

A power quality analyser is normally situated in a network operator’s substation or at a client/facility’s grid connection. The functionality is identical but has different interests and outcomes. Since poor power quality can damage equipment, the client wants to record and document such cases, analyse and take appropriate actions.

Electric motor as possible cause

Accordingly, the operator must conduct its own independent monitoring, to confirm such PQ disturbances occurring. Likewise, the monitoring is needed for providing internal alerts for power quality issues, before any damage is incurred.

Causes and Detection

Voltage sags/dips or swells occur as the result of sudden events within the network, such as short circuits, the energizing of a transformer or the introduction of big loads. For example, a big industrial client turning on an induction motor could cause a notable voltage sag/dips experienced by neighboring facilities as well. Determining this is extremely important for a network operator for preventing such events and for deflecting charges from clients.

When a power quality analyser records a disturbance, the questions above are phrased asking whether the event has taken place upstream or downstream. Upstream indicates occurrence on the generation side / provider side of the analyser; downstream indicates the consumer / load side of the analyser. Other Power Quality concerns include, harmonics, interruptions, fluctuations, notches flicker, frequency, unbalance and transients.

Disturbance Direction

Disturbance Direction Detection with the PM180 Power Analyser

Providing this detection is not trivial and is not featured by most power analysers on the market. The PM180 uses synchronous voltage and current waveforms, recorded before and during an event, to determine the location of the disturbance source. Depending on the characteristics of the fault, the device can apply different methods of analysing the collected data to give the most reliable indication of the direction of the fault.

Voltage Dip, viewed on SATEC’s Expertconnect software

Symmetrical (three-phase) sags/dips and swells are analysed using the relative level of the fault or inrush current and the fundamental power angle. Asymmetric (single-phase and two-phase) sags/dips and swells can be analysed using the negative sequence power angle or, in the case of insufficient information, using the fundamental power angle.

Disturbance Direction Detection

The PM180 Analyser

The PM180 is a Class A, Edition 3, multifunction power quality analyser. Functionality includes: Digital Fault Recorder, PMU (per IEEE C37.1118), PLC controller and more. For more information, visit our PM180 product page.

PM180 Analyser
disturbance direction detection, network disturbances, power quality, voltage sags, voltage swells

NextPrevious

INDUSTRY NEWS & VIEWS

Get fortnightly updates delivered straight to your inbox.

NEWS

  • The Evolution of Smart Metering Standards: What’s Next for Compliance and Innovation?
  • High Precision Metering for NABERS & J9 Compliance
  • Class A vs. Class S Power Quality Meters: Advanced Monitoring for Critical Infrastructure
  • Energy Monitoring for Offshore Wind Projects: Lessons for Australia’s Future
  • Australia’s Renewable Energy Target (RET) – What Role Does Metering Play?

POPULAR POSTS

  • Industry requires smart metering standards to continually evolve.

    The Evolution of Smart Metering Standards: What’s Next for Compliance and Innovation?

    By SATEC (Australia) Pty Ltd | Comments are Closed

    Smart metering has revolutionised the way energy is measured, managed and consumed. With its ability to provide real-time data on energy usage, smart metering plays a vital role in modernising energy grids and improving the efficiency of energy markets. However, as this technology continues to evolve, so too must the standards that govern it.

  • Sustainable building with vertical gardens

    High Precision Metering for NABERS & J9 Compliance

    By SATEC (Australia) Pty Ltd | Comments are Closed

    Achieving superior energy efficiency in buildings is not just about measurement—it’s about measurement accuracy. In Australia, compliance with NABERS (National Australian Built Environment Rating System) and J9 standards under the National Construction Code (NCC) 2022 demands reliable energy data.

  • Data Centre

    Class A vs. Class S Power Quality Meters: Advanced Monitoring for Critical Infrastructure

    By SATEC (Australia) Pty Ltd | Comments are Closed

    Power quality monitoring is a fundamental requirement for ensuring the stability, efficiency and reliability of modern electrical networks, especially in critical infrastructure applications.

  • Offshore wind turbines

    Energy Monitoring for Offshore Wind Projects: Lessons for Australia’s Future

    By SATEC (Australia) Pty Ltd | Comments are Closed

    Offshore wind projects are set to play a crucial role in Australia’s renewable energy transition. While the sector is still in its early stages, insights from established international projects offer valuable guidance.

  • Solar and wind farm for renewable energy

    Australia’s Renewable Energy Target (RET) – What Role Does Metering Play?

    By SATEC (Australia) Pty Ltd | Comments are Closed

    Australia’s Renewable Energy Target (RET) is a key policy driving the transition to a cleaner, greener energy system. By incentivising renewable energy generation, the RET has played a pivotal role in reducing emissions and increasing the share of renewables in Australia’s energy mix.

SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Terms & Conditions
  • Privacy Policy

Recent Posts

  • Industry requires smart metering standards to continually evolve.

    The Evolution of Smart Metering Standards: What’s Next for Compliance and Innovation?

    Smart metering has revolutionised the way energy is measured, managed and consumed. With its ability to provide real-time data on energy usage, smart metering plays a vital role in modernising energy grids and improving the efficiency of energy markets. However, as this technology continues to evolve, so too must the standards that govern it.

    11 March, 2025
  • Sustainable building with vertical gardens

    High Precision Metering for NABERS & J9 Compliance

    Achieving superior energy efficiency in buildings is not just about measurement—it’s about measurement accuracy. In Australia, compliance with NABERS (National Australian Built Environment Rating System) and J9 standards under the National Construction Code (NCC) 2022 demands reliable energy data.

    27 February, 2025
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • About SATEC
  • HARDWARE
    • Phasor Measurement Unit
    • Power Quality Analysers
    • NMI Approved Energy Meters
    • Multi-Channel Energy Meters
    • Current Transformers
    • Expansion Modules
    • All Metering Products
  • SOFTWARE
    • Power Analysis Software (PAS)
    • eXpertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
  • SOLUTIONS
    • Power of Choice Metering
    • NMI Approved Retrofit Energy Metering
    • Frequency Control Ancillary Services (FCAS)
    • Disturbance Direction Detection
    • Phasor Measurement Unit
    • Automatic Demand Response
    • Large-Scale Generation Certificates (LGCs)
  • NEWS
  • DOWNLOADS
    • Manuals & Datasheets
    • Billing & Revenue Metering Catalogue
    • Power Analysis Software (PAS)
    • Current Product Catalogue
  • CONTACT
SATEC (Australia) Pty Ltd