HCS-2000-S · DATASHEET
HCS-2000-S Hall effect split-core DC current sensor datasheet
2,000A Hall Effect split-core DC current sensor.
Transcribed from the SATEC Australia datasheet TBV1.0, 16 September 2026 (PDF, 4 pages, 396 KB). If this page and the PDF differ, the PDF is right; tell us through the contact form.
Overview
Based on the Hall Effect principle, the HCS-2000-S is a split-core sensor designed for measuring DC currents up to 2,000A and is designated for a range of SATEC devices featuring DC metering. Its split-core body clamps around an existing conductor without disconnecting it, so it installs quickly on live plant.
The sensor provides high isolation between its primary and secondary circuits, with built-in protection against overvoltage, reversed polarity and electrical disturbances on the output, so it holds up well in demanding industrial and outdoor environments.
Main features
- High isolation between primary and secondary circuits
- Split-core design for easy installation without disconnecting the conductor
- Protection against overvoltage
- Protection against reversed polarity
- Output protection against electrical disturbances
Feature capabilities
Applications
- Photovoltaic applications
- Battery banks, including monitoring load current and charge current and verifying operation
- Transportation, measuring traction power or auxiliary loads
- Industrial instrumentation
Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.
Specifications
| Nominal input current | 2,000A |
|---|---|
| Linear measuring range | 1.2 × In |
| Overload capacity | 5 × In |
| Nominal output signals | ±20mA |
| Power supply | +15V DC |
| Current consumption | 18mA–50mA + output current |
| Galvanic isolation | 6kV RMS/50Hz/min |
| MTBF | ≥ 100k hours |
| Operating temperature | −40°C to +85°C |
|---|---|
| Storage temperature | −40°C to +100°C |
| Accuracy | ±1.0%FS for 300A–999A ±0.5%FS for 2,000A |
|---|---|
| Linearity | ±0.5%FS for 300A–999A ±0.2%FS for 2,000A |
| + | +15V/+12V power supply |
|---|---|
| − | −15V/−12V power supply |
| M | Output |
| G | Ground |
Connections are made via the on-board offset, gain and Phoenix connector terminals shown in the dimensions drawing overleaf.
| Unit weight | 940–980g |
|---|
Ordering information
HCS-2000-S
The HCS-2000-S is a single fixed-specification model with no configurable order options.
Downloads and related
- Download the datasheet (PDF, TBV1.0, 396 KB)
- Read the PDF in the document library
- All datasheets as web pages
Questions about this datasheet? Use the contact form.