HCS100-S · DATASHEET

HCS100-S Hall effect current sensor datasheet

100A Hall Effect split-core DC current sensor.

Transcribed from the SATEC Australia datasheet TBV1.0, 16 September 2026 (PDF, 3 pages, 295 KB). If this page and the PDF differ, the PDF is right; tell us through the contact form.

Overview

The HCS100-S is a split-core Hall Effect current sensor rated for a primary current of 0–100A, extending accurate DC current measurement to a range of SATEC devices with DC-metering capability. It suits solar, battery storage and other DC power applications where an existing conductor or busbar needs to be measured without being disconnected.

Based on the Hall Effect principle, the sensor provides a proportional secondary output current with a rated accuracy of ±1%, powered from a dual ±15V DC supply. Its split-core housing opens to clamp around the primary conductor, and the output stage is factory-calibrated and should not be adjusted after installation.

Main features

Feature capabilities

Important safety notes

  • Incorrect connection may damage the sensor
  • Output current is positive when the primary current (IP) flows in the direction of the marked arrow
  • The temperature of the primary conductor or busbar running through the sensor must not exceed 100°C

Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.

Specifications

Electrical characteristics
Primary nominal input current0–100 A
Measuring range of primary current0–150 A
Secondary nominal output current20 (±1%)
Power supply±15 V DC (±5%)
Insulation voltageAC / 50 Hz / 1 min
Ambient operating temperature–25°C to +85°C
Ambient storage temperature–40°C to +100°C
WeightNot specified
Connections
Pin 1+15V power supply
Pin 2–15V power supply
Pin 3Output current
Pin 4Ground

Ordering information

HCS100-S

Model
100A Hall Effect split-core DC current sensorHCS100-S