CT-MES · DATASHEET

CT-MES solid core current transformers datasheet

Compact plastic case current transformers for energy metering.

Transcribed from the SATEC Australia datasheet TBV1.0, 30 September 2026 (PDF, 7 pages, 1580 KB). If this page and the PDF differ, the PDF is right; tell us through the contact form.

Overview

The CT-MES range is a family of compact solid core current transformers for energy metering and power monitoring. It is built for switchboard builders, electrical contractors and facility teams who need an accurate CT that fits tight panel space.

Eight frame sizes cover primary currents from 5A to 3000A with a 5A or 1A secondary. Every unit has integral hinged terminal covers that can be sealed and a self-extinguishing Class V0 case. Choose DIN rail, panel bracket or busbar clip mounting to suit the installation.

Main features

Feature capabilities

CT-MES-62 Series

  • 62/20B, 62/20, 62/30 and 62/40. Narrow 62mm body for 5/5A to 400/5A.

CT-MES-80 Series

  • 80/30 and 80/40. 80mm body with fixing feet for 30/5A to 500/5A.

CT-MES-100 and 140 Series

  • 100/60 and 140/100. Large windows for 600/5A to 3000/5A.

Compact Solid Core Design

  • Closed solid core with the primary conductor passed through the window
  • Plastic case with a much smaller footprint than conventional CTs
  • Eight frame sizes so one family covers most LV metering points
  • CT-MES-62/20B low current model with an integral primary bar for 5/5A to 150/5A

Metering Accuracy

  • Class 0.5 ratings available in all eight frame sizes
  • Class 1.0 and Class 3.0 ratings for general monitoring and low ratios
  • Rated output of 1.5VA to 25VA listed per ratio in the ratings tables
  • Select an output that covers the meter burden plus the secondary cabling

Flexible Mounting Options

  • Each CT-MES mounts the way the switchboard needs it. Fix it to DIN rail through an adapter, to a panel with the metal bracket or directly onto a busbar with a support clip.

Safety and Protection

  • Instrument security factor FS < 5 limits secondary current during faults to help protect connected meters
  • Short-time thermal current of 60 × In
  • Insulation level 0.72/3kV at 50Hz to 60Hz
  • Self-extinguishing Class V0 casing
  • Sealable terminal covers deter tampering and protect live terminals

Part of a Complete SATEC Metering System

  • Pair CT-MES transformers with any SATEC power meter that accepts 5A or 1A current inputs to build a complete metering point from one supplier. Where the conductor cannot be disconnected choose split core current transformers. For high accuracy applications see the HACS high accuracy current sensors. Browse the full range of current transformers for energy meters.

Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.

Specifications

Electrical
Rated primary current5A to 3000A (model dependent)
Rated secondary current5A or 1A
Rated frequency50Hz to 60Hz
Insulation level0.72/3kV
Short-time thermal currentIth = 60 × In
Instrument security factorFS < 5
Accuracy and output
Accuracy class0.5, 1.0 or 3.0 (subject to burden)
Rated output1.5VA, 2.5VA, 3.75VA, 5VA, 10VA, 15VA, 20VA, 25VA
Ratings by ratioSee ratings tables, pages 4 to 6
Construction
TypeSolid core, window type
CasingPlastic, self-extinguishing Class V0
TerminalsIntegral hinged terminal covers, sealable
Frame sizes8
DimensionsSee model overview and drawings
Mounting
DIN railVia DIN rail adapter
PanelMetal mounting bracket or fixing feet
BusbarBusbar support mounting clip
Model overview: CT-MES-62/20B
Ratio range5/5A to 150/5A
Accuracy class0.5, 1.0
Rated output1.5VA to 2.5VA
W × H × D (mm)68 × 87.5 × 57 (79 incl. primary terminals)
Max. cableIntegral primary bar
Model overview: CT-MES-62/20
Ratio range30/5A to 200/5A
Accuracy class0.5, 1.0, 3.0
Rated output1.5VA to 5VA
W × H × D (mm)68 × 87.5 × 57
Max. cableØ22mm
Model overview: CT-MES-62/30
Ratio range30/5A to 200/5A
Accuracy class0.5, 1.0, 3.0
Rated output1.5VA to 5VA
W × H × D (mm)68 × 87.5 × 57
Max. cableØ30mm
Model overview: CT-MES-62/40
Ratio range60/5A to 400/5A
Accuracy class0.5, 1.0
Rated output1.5VA to 10VA
W × H × D (mm)68 × 87.5 × 57
Max. cableØ30mm
Model overview: CT-MES-80/30
Ratio range30/5A to 200/5A
Accuracy class0.5, 1.0, 3.0
Rated output1.5VA to 5VA
W × H × D (mm)80 × 86.5 × 77
Max. cableØ30mm
Model overview: CT-MES-80/40
Ratio range100/5A to 500/5A
Accuracy class0.5, 1.0
Rated output2.5VA to 10VA
W × H × D (mm)80 × 86.5 × 77
Max. cableØ30mm
Model overview: CT-MES-100/60
Ratio range600/5A to 1200/5A
Accuracy class0.5, 1.0
Rated output10VA to 20VA
W × H × D (mm)101 × 118 × 77.4
Max. cableØ50mm
Model overview: CT-MES-140/100
Ratio range800/5A to 3000/5A
Accuracy class0.5, 1.0
Rated output15VA to 25VA
W × H × D (mm)140 × 155 × 53
Max. cableØ86mm

Dimensions are overall and taken from the factory drawings. Busbar window sizes are shown on each drawing on pages 4 to 6.

CT-MES-62/20B · 5/5A to 150/5A: rated output (VA) by rated current (A)
5/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
10/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
15/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
20/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
25/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
30/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
40/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
50/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
60/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
75/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
100/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
150/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
CT-MES-62/20 · 30/5A to 200/5A: rated output (VA) by rated current (A)
30/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 1.5
40/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 1.5
50/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
60/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
75/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
80/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
100/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
150/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
200/5Class 0.5: 3.75 · Class 1.0: 5 · Class 3.0: n/a

Ratings shown are for a 5A secondary. n/a means the ratio is not offered in that accuracy class. Contact SATEC for 1A secondary ratings. All dimensions in millimetres.

CT-MES-62/30 · 30/5A to 200/5A: rated output (VA) by rated current (A)
30/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 2.5
40/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 2.5
50/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 2.5
60/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
75/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
100/5Class 0.5: 1.5 · Class 1.0: 2.5 · Class 3.0: n/a
150/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
200/5Class 0.5: 3.75 · Class 1.0: 5 · Class 3.0: n/a
CT-MES-62/40 · 60/5A to 400/5A: rated output (VA) by rated current (A)
60/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
75/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
100/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
150/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
200/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
250/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
300/5Class 0.5: 3.75 · Class 1.0: 5 · Class 3.0: n/a
400/5Class 0.5: 5 · Class 1.0: 10 · Class 3.0: n/a
CT-MES-80/30 · 30/5A to 200/5A: rated output (VA) by rated current (A)
30/5Class 0.5: n/a · Class 1.0: n/a · Class 3.0: 2.5
50/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
60/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
75/5Class 0.5: n/a · Class 1.0: 1.5 · Class 3.0: n/a
100/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
150/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
200/5Class 0.5: 5 · Class 1.0: 5 · Class 3.0: n/a

Ratings shown are for a 5A secondary. n/a means the ratio is not offered in that accuracy class. Contact SATEC for 1A secondary ratings. All dimensions in millimetres.

CT-MES-80/40 · 100/5A to 500/5A: rated output (VA) by rated current (A)
100/5Class 0.5: n/a · Class 1.0: 2.5 · Class 3.0: n/a
150/5Class 0.5: 2.5 · Class 1.0: 3.75 · Class 3.0: n/a
200/5Class 0.5: 3.75 · Class 1.0: 5 · Class 3.0: n/a
250/5Class 0.5: 3.75 · Class 1.0: 5 · Class 3.0: n/a
300/5Class 0.5: 5 · Class 1.0: 5 · Class 3.0: n/a
400/5Class 0.5: 5 · Class 1.0: 10 · Class 3.0: n/a
500/5Class 0.5: 5 · Class 1.0: 10 · Class 3.0: n/a
CT-MES-100/60 · 600/5A to 1200/5A: rated output (VA) by rated current (A)
600/5Class 0.5: 10 · Class 1.0: 15
800/5Class 0.5: 10 · Class 1.0: 15
1000/5Class 0.5: 10 · Class 1.0: 20
1200/5Class 0.5: 15 · Class 1.0: 20
CT-MES-140/100 · 800/5A to 3000/5A: rated output (VA) by rated current (A)
800/5Class 0.5: 15 · Class 1.0: 20
1000/5Class 0.5: 15 · Class 1.0: 20
1200/5Class 0.5: 15 · Class 1.0: 20
1500/5Class 0.5: 15 · Class 1.0: 20
1600/5Class 0.5: 15 · Class 1.0: 20
2000/5Class 0.5: 15 · Class 1.0: 25
2500/5Class 0.5: 15 · Class 1.0: 25
3000/5Class 0.5: 15 · Class 1.0: 25

Ratings shown are for a 5A secondary. n/a means the ratio is not offered in that accuracy class. Contact SATEC for 1A secondary ratings. All dimensions in millimetres. Accuracy Class 0.5, 1.0 and 3.0 subject to rated burden (p. 7).

Standards compliance

Instrument Transformers

  • IEC 61869-2: Additional requirements for current transformers
  • AS 61869.2: Additional requirements for current transformers
  • IEC 60044-1: Current transformers
  • AS 60044.1: Current transformers

National Standards

  • BS 7626: Current transformers
  • VDE 0414: Instrument transformers

Construction

  • Self-extinguishing Class V0 casing
  • Sealable terminal covers

Ordering information

MODEL · PRIMARY / SECONDARY · ACCURACY CLASS · RATED OUTPUT · OPTIONS

Model
5/5A to 150/5A, integral primary barCT-MES-62/20B
30/5A to 200/5A, Ø22mmCT-MES-62/20
30/5A to 200/5A, Ø30mmCT-MES-62/30
60/5A to 400/5A, Ø30mmCT-MES-62/40
30/5A to 200/5A, Ø30mmCT-MES-80/30
100/5A to 500/5A, Ø30mmCT-MES-80/40
600/5A to 1200/5A, Ø50mmCT-MES-100/60
800/5A to 3000/5A, Ø86mmCT-MES-140/100
Primary / secondary
Primary current 5A to 3000A (see ratings tables)e.g. 100
5A secondary/5
1A secondary/1
Accuracy class
Class 0.50.5
Class 1.01.0
Class 3.0 (selected low ratios)3.0
Options
Rated output per ratings tableVA
Mounting: DIN rail, panel or busbarSpecify

Example: CT-MES-62/30 · 100/5A · Class 0.5 · 1.5VA