+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • About SATEC
  • HARDWARE
    • Phasor Measurement Unit
    • Power Quality Analysers
    • NMI Approved Energy Meters
    • Multi-Channel Energy Meters
    • Current Transformers
    • Expansion Modules
    • All Metering Products
  • SOFTWARE
    • Power Analysis Software (PAS)
    • eXpertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
  • SOLUTIONS
    • Power of Choice Metering
    • NMI Approved Retrofit Energy Metering
    • Frequency Control Ancillary Services (FCAS)
    • Disturbance Direction Detection
    • Phasor Measurement Unit
    • Automatic Demand Response
    • Large-Scale Generation Certificates (LGCs)
  • NEWS
  • DOWNLOADS
    • Manuals & Datasheets
    • Billing & Revenue Metering Catalogue
    • Power Analysis Software (PAS)
    • Current Product Catalogue
  • CONTACT

HACS: HIGH ACCURACY CURRENT SENSORS

HACS stands for High Accuracy Current Sensor which has three major advantages over conventional current transformers (CTs). These advantages are that they possess increased accuracy over commonly used CTs, they use an internal short circuit method which allows them to be left open without shorting bars and they have a low current output that allows the use of cables with small cross section.

All HACS are supplied with 8ft / 2.5m cable.Maximum cable length: 650ft / 200m. The selection of HACS varies according to your choice of instruments.

Split Core HACS (click on order number for more information)

CS05S – 0-20 Amp (ID 16mm /0.62”)

CS1S – 0-100 Amp (ID 16mm / 0.63”)

CS1H – 0-100 Amp (ID 13mm / 0.05”)

CS2S – 0-200 Amp (ID 24.5×23.1mm / 0.96×0.9”)

CS2SL – 0-200 Amp (ID 43x33mm / 1.69×1.3”)

CS4S – 0-400 Amp (ID 43x33mm / 1.69×1.3”)

CS8S – 0-800 Amp (ID 80x50mm / 3.1×1.9”)

CS12S – 0-1200 Amp (ID 120x80mm / 4.7×3.1”)

CS20S – 0-2000 Amp (ID 160x80mm / 6.3×3.15”)

CS30S – 0-3000 Amp (ID 160x80mm / 6.3×3.15”)

Solid Core HACS (click on order number for more information)

CS1 – 0-100 Amp (ID 12mm / 0.47”)

CS1L – 0-100 Amp (ID 23mm / 0.9”)

CS2 – 0-200 Amp (ID 23mm / 0.9”)

CS4 – 0-400 Amp (26mm / 1.02”)

CS8 – 0-800 Amp (ID 100×32/62mm / 4×1.28/2.44”)

Meters suitable for HACS use

PM172

EM133

PM175

SA330 ezPAC

BFM136

PM135EH

PM130EH

EM132

Additional HACS Information

HACS Datasheet

HACS Datasheet – PM130 / PM135 Typical Connection

HACS Frequently Asked Questions

HACS Current Transformers

HACS: High Accuracy Current Sensors Range

HACS - High Accuracy Current Sensors - CS05S

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS05S / RS5*

HX0140

20A

Ø 16mm /0.62”

Split

0.5%

98.2g / 0.22 lbs

*Used only with RS5 Input meters

HACS - High Accuracy Current Sensors - CS1

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS1

EL0072

100A

Ø 12mm / 0.47”

Solid

0.1%

156.4g / 0.34 lbs

HACS - High Accuracy Current Sensors - CS1L

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS1L

EL0115

100A

Ø 23mm / 0.9”

Solid

0.1%

206.3g / 0.45 lbs

HACS - High Accuracy Current Sensors - CS05S

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS1S

HX0118

100A

Ø 16mm / 0.63”

Split

0.5%

103.4g / 0.23 lbs

HACS - CS1H-HX0161

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS1H

HX0161

100A

Ø 13mm / 0.05”

Split

0.1 / 0.2

280g / 0.6lbs

High Accuracy Current Sensors - CS2-EL0142

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS2

EL0142

200A

Ø 23mm / 0.9”

Solid

0.1

206.3g / 0.45 lbs

HACS - High Accuracy Current Sensors - CS2S

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS2S

HX0145

200A

24.5x23.1mm / 0.96x0.9”

Split

0.5

160g / 0.34lbs

High Accuracy Current Sensors - CS2SL-HX0156

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS2SL

HX0156

200A

43x33mm / 1.69x1.3”

Split

0.5

450g / 1lbs

HACS - High Accuracy Current Sensors - CS4

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS4

EL0117

400A

Ø 26mm / 1.02”

Solid

0.1

214g / 0.47lbs

High Accuracy Current Sensors - CS4S-HX0157

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS4S

HX0157

400A

43x33mm / 1.69x1.3”

Split

0.5

450g / 1lbs

HACS - High Accuracy Current Sensors - CS8

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS8

EL0125

800A

100x32/62mm / 4x1.28/2.44”

Solid

0.1

450g / 1lbs

High Accuracy Current Sensors - CS8S-HX0158

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS8S

HX0158

800A

80x50mm / 3.1x1.9”

Split

0.5

900g / 1.9lbs

High Accuracy Current Sensors - CS12S-HX0153

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS12S

HX0153

1200A

120x80mm / 4.7x3.1”

Split

0.5

1.25kg / 2.75lbs

High Accuracy Current Sensors - CS30S-HX0155

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS20S

HX0154

2000A

160x80mm / 6.3x3.15”

Split

0.5

4.3kg / 9.4lbs

High Accuracy Current Sensors - CS30S-HX0155

Order String:

Catalog No.

Max Current

Window

Core

Accuracy %

Weight

CS30S

HX0155

3000A

160x80mm / 6.3x3.15”

Split

0.5

4.3kg / 9.4lbs

HACS FREQUENTLY ASKED QUESTIONS

What is the difference between HACS and regular CT?

HACS stands for High Accuracy Current Sensor which has three major advantages over conventional CTS:

  • Better accuracy than commonly used CTs
  • Internal short circuit method which allows it to be left opened without shorting bars
  • Low current output that allows to use cables with small cross section

Can I use conventional CTs?

The inputs are designed for our HACS and do not include protection against hazards that are typical with CTs. Since that SATEC does not provide product warranty when used with non SATEC HACS.

What is the maximum distance between the HACS and the meter?

The HACS are provided with 1.5m cable, but can be extended up to 200m while keeping the high accuracy class.

What is the difference between nominal, maximum and overload current?

Nominal current – the current to which the meter is calibrated to, in which it provides the highest accuracy

Maximum current – the highest current that the meter can measure

Overload current – the highest current that the meter can withstand without damage. There are few levels, depending on the time.

When stating 1A or 5A, it is the nominal current and, unless otherwise stated, the maximum current is twice this value (2A or 10A). When stating higher current values it the maximum current and, unless otherwise stated, the nominal current is half of this value (i.e., EM133-100A is calibrated to 50A).

What are the difference current inputs for PM130 and PM135?

There is a selection of 4 current inputs:

  • 1A – for use with ../1A conventional CT, typically in MV and HV applications
  • 5A – for use with ../5A conventional CT. when used with ../1A CT, we recommend making few turns in order to improve the accuracy
  • RS5 – similar operation and performance to the 5A, but with remote split core sensors for easy retrofit installation. The added price includes set of 3 Split Core HACSes
  • HACS – PM130 that is designed for use of various HACSes, from 100A to 1200A. It is required to purchase 3 HACSes for this product, either solid core or split core

What are the different current inputs for EM132 and EM133?

The EM132 and EM133 has four current input channels – 1A, 5A and HACS are similar to the PM130, plus direct connection of 100A.

Currently there is no HACS option for EM132/EM133.

What are the different current inputs for PM175?

The PM175 has five different current inputs – four as the PM130 (1A, 5A, RS5 and HACS) plus special design for pole-top sensors.

What are the different current inputs for PM174?

The PM174 has six different current inputs – five as the PM175 plus a special model name DFR, which stands for Digital Fault Recorder. It includes a set of 3 split core 100A HACS which are calibrated to 5A, plus software modifications to records faults of up to 100A using the same current channels.

What are the different current inputs for SA320 ezPAC?

The SA320 has one set of current inputs, which internally are split between measurement channels and protection CT inputs. There are 3 options:

  • 1A – the measurement channels are calibrated for 1A and the protection channels to 20A
  • 5A – the measurement channels are calibrated for 5A and the protection channels to 150A
  • CS1S –remote connection of 100A split core HACS, calibrated to 5A (measurement) and 100A (protection)

What are the different current inputs for SA330 ezPAC?

The SA330 has two set of current inputs: measurement channels and protection CT inputs, each one with different select as follows:

  • Measurement inputs:
    • 1A – the measurement channels are calibrated for 1A
    • 5A – the measurement channels are calibrated for 5A
  • Protection CT inputs:
    • 150A (leave the second selection in the order string empty) – connection of protection CT secondary of up to 150A to the terminals
    • CS1S – remote connection of 100A split core HACS designed to be connected around the secondary of protection CTs of up to 100A

Discuss your metering needs with us

SATEC (Australia) Pty Ltd

We look forward to discussing your next project. Fill out the form or pick up the phone, we will be happy to help.

PO Box 82, Mulgoa NSW 2745

Phone: +61 2 4774-2959

Email: [email protected]

    SATEC Australia logo

    SATEC – Solutions And Technology for Energy Control

    SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

    The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

    Quick Find

    • Contact
    • Metering Products
    • Energy Management Software
    • News – Events – Updates
    • Downloads
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Terms & Conditions
    • Privacy Policy

    Recent Posts

    • Industry requires smart metering standards to continually evolve.

      The Evolution of Smart Metering Standards: What’s Next for Compliance and Innovation?

      Smart metering has revolutionised the way energy is measured, managed and consumed. With its ability to provide real-time data on energy usage, smart metering plays a vital role in modernising energy grids and improving the efficiency of energy markets. However, as this technology continues to evolve, so too must the standards that govern it.

      11 March, 2025
    • Sustainable building with vertical gardens

      High Precision Metering for NABERS & J9 Compliance

      Achieving superior energy efficiency in buildings is not just about measurement—it’s about measurement accuracy. In Australia, compliance with NABERS (National Australian Built Environment Rating System) and J9 standards under the National Construction Code (NCC) 2022 demands reliable energy data.

      27 February, 2025
    © 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
    • About SATEC
    • HARDWARE
      • Phasor Measurement Unit
      • Power Quality Analysers
      • NMI Approved Energy Meters
      • Multi-Channel Energy Meters
      • Current Transformers
      • Expansion Modules
      • All Metering Products
    • SOFTWARE
      • Power Analysis Software (PAS)
      • eXpertpower SaaS – EMS, Billing, Power Quality
      • Meter Data Management (MDM)
    • SOLUTIONS
      • Power of Choice Metering
      • NMI Approved Retrofit Energy Metering
      • Frequency Control Ancillary Services (FCAS)
      • Disturbance Direction Detection
      • Phasor Measurement Unit
      • Automatic Demand Response
      • Large-Scale Generation Certificates (LGCs)
    • NEWS
    • DOWNLOADS
      • Manuals & Datasheets
      • Billing & Revenue Metering Catalogue
      • Power Analysis Software (PAS)
      • Current Product Catalogue
    • CONTACT
    SATEC (Australia) Pty Ltd