+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC
NextPrevious
HACS - High Accuracy Current Sensors - CS1L

High Accuracy Current Sensors (HACS)

By SATEC (Australia) Pty Ltd | Product News | Comments are Closed | 3 February, 2016 | 0

SATEC’s range of current transformers, referred to as High Accuracy Current Sensors (HACS), are designed for flexibility for new and retrofit applications for energy metering. SATEC HACS in combination with SATEC electrical metering hardware EM132, EM133, PM130EH, PM135EH and BFM136 provide a complete system measuring accuracy of Class 1.0 or better (energy meter + HACS = Class 1.0 or better).

The HACS can be extended up to 200 metres from any SATEC meter using 1.5mm2 cable providing solutions where restrictions to access to loads is difficult due to installation problems.

SATEC’s High Accuracy Current Sensors have an accuracy Class 0.5, providing readings as low as 0.1% of the current range. HACS are available in 100A, 200A, 400A, 800A, 1200A, 2000A and 3000A current ranges.

Interfacing with third party current transformers already installed in the field with existing installations is possible. This is achieved with the SATEC HACS via the secondary of the 5A or 1A input with appropriate programming of the SATEC meter to suit the installation.

accuracy class, current sensors, current transformers, energy management

NextPrevious

BOOK AN ONLINE MEETING

INDUSTRY NEWS & VIEWS

Get fortnightly updates delivered straight to your inbox.

Energy Management Knowledge Base

NEWS

  • Battery Energy Storage Systems (BESS): The DC Metering Checklist
  • PMU Grid Events: What They Are, Why They Matter and How to Measure Them Better
  • Energy Usage in Data Centres: What’s Driving It, How to Measure It and How to Control It
  • Poor Power Factor: What It Is, Why It Matters and How to Fix It
  • Energy Monitoring: Why It Matters More Than Ever (and How to Get It Right)
SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Energy Management Knowledge Base
  • Terms & Conditions
  • Privacy Policy

Recent Posts

  • Battery Energy Storage Systems (BESS)

    Battery Energy Storage Systems (BESS): The DC Metering Checklist

    BESS projects succeed or fail on measurement. Use this DC metering checklist to improve accuracy, integration, commissioning and performance reporting with confidence.

    22 January, 2026
  • PMU Grid Events occurring in a substation

    PMU Grid Events: What They Are, Why They Matter and How to Measure Them Better

    Learn what PMU grid events are, how phasor measurement units detect disturbances and why high-resolution monitoring matters – plus how SATEC provides the metering solution.

    21 January, 2026
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC
SATEC (Australia) Pty Ltd