+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC
NextPrevious
Dual Voltage Input Module (VIM)

The Voltage Input Module (VIM): One BFM, Two Power Sources, Zero Guesswork

By SATEC (Australia) Pty Ltd | Digital Fault Recorders (DFR), Featured, Multi-Circuit Monitors, Product News, Product Releases | Comments are Closed | 10 October, 2025 | 0

When your site runs with two independent power sources, think dual transformers or a grid + solar export setup, accurate energy measurement gets tricky. Active power depends on both voltage and current (P = V × I × cosφ). If your meter “sees” current from one source but voltage from another, power factor is wrong and your energy totals drift.

SATEC’s new dual Voltage Input Module (VIM) solves this elegantly by giving the BFM II Branch Feeder Monitor a second three-phase voltage input so each load is paired with the correct source, every time.

What the VIM Does (and Why It Matters)

Dual-source accuracy

The VIM adds an extra three-phase voltage input to the BFM II, letting the meter assign each measured load/current to the correct source. That removes the angle/phase ambiguity and restores true active power and energy accuracy under dual-source conditions.

All your circuits on one device

With VIM installed, a single BFM can monitor up to 36 current channels (e.g., 12 three-phase or 36 single-phase circuits, or any mix), replacing a cluster of single meters with one scalable system. Channel-to-source assignment is done in SATEC’s Power Analysis Software (PAS) for quick setup and reconfiguration.

Lower installed cost, smaller footprint

The multi-circuit design was built to simplify and reduce costs – fewer meters to buy, wire, mount and maintain. Adding VIM extends those savings to dual-source sites that used to require multiple meters just to keep measurements straight.

High-Impact Applications

Transformer efficiency, measured directly. Monitor the MV side and LV side with a single BFM + VIM to calculate transformer losses in real time, no extra MV meter required.

Inverter health check for renewables. The BFM measures individual harmonics per current channel up to the 25th, helping you spot failing inverters that often show rising harmonic content before outright failure.

Retrofit without downtime. Using split-core HACS CTs and the BFM’s retrofit-friendly design, you can install and digitalise a substation without a shutdown, accelerating projects and avoiding outage costs.

Built for Substations and Complex Sites

Serious I/O for situational awareness. Up to 72 digital inputs capture external status signals (breakers, relays, access alarms), analogue inputs bring in feeder/transformer telemetry (temperature, oil level), and up to 18 relays can control breakers or raise alarms.

SCADA-ready out of the box. Communicate over TCP, serial, or 4G, and integrate with SCADA systems via IEC 60870-5-101/104, Modbus, or DNP3.0. There’s even a Digital Fault Recorder (BFM-DFR) option to record faults up to 40× In—a cost-effective way to add disturbance visibility.

Revenue metering + PQ insights. Beyond multi-circuit billing (including revenue-class metering), the BFM platform supports individual harmonic analysis and works with SATEC’s High Accuracy Current Sensors (HACS)—solid or split-core from 5A to 3,000A with accuracy up to 0.1%. You can even connect to a 5A secondary from existing protection-relay CTs for ease of  retrofitting via SATEC’s HACS / CTs.

Key Benefits at a Glance

Accuracy with two sources: Correct voltage/current pairing eliminates phase-angle errors and protects energy totals.

One system, many circuits: Scale to dozens of loads per BFM, configured quickly in PAS.

Lower cost to deploy: Fewer meters, less wiring, smaller enclosures—and reduced maintenance.

Condition-based insights: Harmonics per channel reveal inverter or feeder issues early.

Substation-grade integration: Rich I/O, open protocols, and optional DFR to close the loop from measurement to action.

Retrofit friendly: Split-core CTs and live-install workflows minimise disruption.

Make Dual-Source Metering Simple

In short, pairing the VIM with the BFM II gives you accurate metering across dual sources, scalable multi-circuit coverage, and substation-ready integration—without the cost and complexity of multiple meters. If you’re planning a retrofit, chasing cleaner energy data, or need tighter SCADA visibility, this is a smart, future-proof step.

Ready to explore your site’s fit? Contact the SATEC team to talk through your application and get a tailored recommendation.

Frequently Asked Questions - Voltage Input Module (VIM)

What problem does the Voltage Input Module (VIM) solve?

Dual-source sites (e.g., two transformers, grid + PV) often mis-pair voltage and current, corrupting power/energy totals. VIM adds a second three-phase voltage input so the Branch Feeder Monitor (BFM) assigns each load to the correct source and keeps measurements accurate.

How many circuits and sources can I meter?

A single BFM with VIM meters up to 36 current channels (e.g., 12 three-phase or 36 single-phase) while handling two independent voltage sources, with source assignment managed in Power Analysis Software (PAS).

Will it integrate with my SCADA and protection?

Yes. Communication over TCP /serial /4G with IEC 60870-5-101/104, Modbus and DNP3.0; up to 72 digital inputs, analogue inputs for transformer telemetry, up to 18 relays for control and an optional Digital Fault Recorder (DFR) for fault recording to 40× In.

dual voltage input, dual voltage input module, voltage input module

NextPrevious

BOOK AN ONLINE MEETING

INDUSTRY NEWS & VIEWS

Get fortnightly updates delivered straight to your inbox.

Energy Management Knowledge Base

NEWS

  • Power Metering for Hospitals and Healthcare Facilities
  • Why Choosing the Right Electricity Sub Meter Matters for Accurate Billing
  • Energy Metering for Data Centres and the AI Boom
  • AC vs DC Power: Differences and Applications
  • SATEC EM133-XM Smart Energy Meter With Ethernet Connectivity
SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Energy Management Knowledge Base
  • Terms & Conditions
  • Privacy Policy

Recent Posts

  • Power Metering for Hospitals and Healthcare Facilities

    Discover how power metering helps hospitals improve reliability, cut energy costs and support decarbonisation. SATEC’s metering solutions support critical healthcare facilities.

    10 December, 2025
  • Why Choosing the Right Electricity Sub Meter Matters for Accurate Billing

    Choosing the right electricity sub meter is essential for accurate, compliant energy billing and tenant trust. Discover what to look for and how SATEC’s sub metering solutions can help.

    9 December, 2025
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC
SATEC (Australia) Pty Ltd