+61 2 4774-2959
sales@satec-global.com.au
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • About SATEC
  • HARDWARE
    • Phasor Measurement Unit
    • Power Quality Analysers
    • NMI Approved Energy Meters
    • Multi-Channel Energy Meters
    • Current Transformers
    • Expansion Modules
    • All Metering Products
  • SOFTWARE
    • Power Analysis Software (PAS)
    • eXpertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
  • SOLUTIONS
    • Power of Choice Metering
    • NMI Approved Retrofit Energy Metering
    • Frequency Control Ancillary Services (FCAS)
    • Disturbance Direction Detection
    • Phasor Measurement Unit
    • Automatic Demand Response
    • Large-Scale Generation Certificates (LGCs)
  • NEWS
  • DOWNLOADS
    • Manuals & Datasheets
    • Billing & Revenue Metering Catalogue
    • Power Analysis Software (PAS)
    • Current Product Catalogue
  • CONTACT

NEW! eXpertPRO™ DIN EM235 POWER QUALITY ANALYSER

IEC61850 Advanced Power Quality Analyser

eXpertPRO DIN EM3250

The eXpertPRO DIN series compact intelligent electronic device (IED) is a DIN Rail power quality analyser with a small form factor design, the eXpertPRO DIN EM235 DIN-rail combines metering, power quality and control input/output functions that provide an advanced solution for substation, industrial automation and commercial energy management applications. Incorporating a unique collection of powerful features commonly found in numerous specialised measurements and recording equipment utilised in substation and industrial environments. Although the device is primarily designed as an inexpensive add-on to expand the capabilities of the existing utility substation protection equipment, it is well suited for a wide range of industrial and commercial applications with high input currents whenever extensive power quality monitoring is required.

Highlighted Features

IED with IEC 61850 protocol (Option)

Dual Ethernet Ports (Daisy Chain or independent)

Waveform capture and recording

Add on modules (DI/DO/AI etc.)

Modbus Master

USB port (Type C)

4GB on-board memory

Timers, Counters

Class 0.2S accuracy per AS/IEC 62053-22

WEB Server (future release)

Model

eXpertPRO DIN EM235 Power Quality Analyser: Measurement of AC voltage, current, power, frequency, harmonics, power quality analysis with waveform capabilities, sags, swells, energy watt and var hours. Up to 12 data logs for interval/load profiling, input/output control capabilities, complete with 1.77″ TFT colour display including bar-graph for load reference. User selection up to 16 parameters per data log, providing up to 192 electrical values.

Current Inputs
1A-5A universal current input with maximum continuous current 10A
HACS: 40mA input for SATEC’s High Accuracy Current Sensors (HACS)

DOWNLOAD DATASHEETCONTACT US

eXpertPRO EM235 Power Quality Analyser Features

  • Up to 26 external digital triggers from protection relays; on-board zero-sequence currents and volts, current and voltage
    unbalance; coincident volt magnitude, fault waveforms and fast RMS trace; cross triggering between multiple devices via
    digital inputs for synchronous event capture and recording.
  • Event recorder for logging internal diagnostics events, control events and I/O operations.
  • Eight Fast Waveform recorders: 7-channel simultaneous recording; selectable AC sampling rate of 32, 64, 128 or 256 samples per cycle; 20 pre-fault cycles; synchronised waveforms from multiple devices in a single plot; exporting waveforms in COMTRADE and PQDIF file formats.
  • Embedded Programmable Controller: 64 control setpoints, OR/AND logic, extensive triggers, programmable thresholds and delays, relay control, event-driven data recording, cross triggering between multiple devices via the Ethernet for synchronous event capture and recording – up to sixteen triggering channels.
  • High Accuracy Class 3-phase power meter: True RMS, volts, amps, powers, power factors, unbalance, and neutral current
  • Class 0.2S AS/IEC 62053-22 Watt-Hours Class 0.2 C12.20 four-quadrant active and reactive energy polyphase static meter
  • Demand Meter: amps, volts, harmonic demands.
  • Precise Energy and Power Demand Meter: Time-of-Use (TOU), 16 Summary (totalisation) and TOU energy and demand
    registers for substation energy management; accumulation of energy pulses from external watt-meters; block and
    sliding demands; up to 64 energy sources.
  • Directional Power Flow
  • Harmonic Analyser: up to 63rd harmonic volts, amps, directional power harmonics, power factor; phasor, symmetrical
    components.
  • 32 digital counters for counting pulses from 26 external sources and 6 internal events.
  • 16 programmable timers from 1 cycle to 24 hours for periodic recording and triggering operations on a time basis.
  • Backup power supply unit (optional)
  • 4 slots for optional I/O/COM modules.
  • TCP notification client for communicating with a remote MODBUS/TCP server on events or periodically on a time basis, with any IP enable communication port
  • Up to 4GB FLASH disk Memory for long term waveform and data recording.
  • Real Time Clock; Internal clock with battery backup for three years Real-Time Clock retention time

AC Outputs

The eXpertPRO DIN power quality analyser series is provided with a set of fully isolated AC inputs for connecting to the AC feeders:

  • Three isolated AC voltage inputs (10 to 1000 VAC direct line-to-line input voltage)
  • Three isolated AC current inputs plus a fourth current input
  • 50/60 Hz automatic frequency range

Auxiliary Power Supply Optional Backup Power

  • Auxiliary AC/DC Power Supply Module:
    AC: 85-264 VAC
    DC: 100-400 VDC 5W AC/DC

Software

  • Free licensed Power Analyser Software (PAS)
  • Licensed eXpertPower Cloud Software
  • Licensed eXpertPower Server Software

Communication, I/O and Power Supply Options

  • The eXpertPRO DIN series has various communication and Input/Output port capabilities with optional expansion modules.
  • Expansion modules may be any combination of three I/O or communication modules and the fourth for back-up power
    supply module.

Standard built-in I/O ports

  • 2 optically isolated inputs, 24VDC dry contact; programmable de-bounce time from 1 ms to 1 s; control setpoints, 1pps time synchronization; 1ms sampling rate
  • 1 Solid State Relay output; unlatched, latched and pulse operations, failsafe operation for alarm notifications;
    programmable pulse width; direct remote relay control through communications
  • 1 optically isolated analog input; -1mA to 20mA

Additional Optional Digital I/O Modules Maximum 3 *Modules

  • 8 DI: (AC/DC bipolar) 8-channel digital input module: 8 optically isolated inputs per module; options for dry contacts: 12, 48, 125, 250V; programmable de-bounce time from 1 ms to 1 sec; control setpoints, pulse counters and Energy/TOU subsystem, 1pps time synchronization; 1ms sampling rate.
  • 4DO: – 4 relays per module, (SSR or EMR)

Communications

The eXpertPRO DIN series has extensive communication capabilities:

Standard built-in I/O ports

  • Serial communication port; RS-485, up to 115,200 bps, MODBUS RTU/ASCII, DNP3.0 and IEC 60870-5-101 protocols
  • Infrared port; up to 115,200 bps, MODBUS RTU/ASCII, DNP3.0 protocols and IEC 62056-21 (DLMS) protocol (future release)
  • Built-in Dual Ethernet 10/100 Base-T port; MODBUS/TCP, DNP3.0/TCP, IEC 60870-5-104 protocols and optional IEC
    61850 protocol.
  • Up to 10 non-intrusive simultaneous connections per Ethernet port, Telnet service port
  • Built-in second Ethernet 10/100 Base-T port; daisy chain capability or 2 independent Ethernet port
  • USB 2.0 port; Device Full speed, USB-C connector

Standards Compliance

Accuracy

  • Meets AS/IEC62053-22:2003, class 0.2S – WattHours
  • Meets AS/EC 62053-24:2014, class 0.5S – VarHours
  • Meets ANSI C12.20 –2015, Current class 10, accuracy class 0.2

Electromagnetic Immunity:

  • Comply with IEC 61000-6-2:
  • IEC 61000-4-2 level 3: Electrostatic Discharge
  • IEC 61000-4-3 level 3: Radiated Electromagnetic RF Fields
  • IEC 61000-4-4 level 3: Electric Fast Transient
  • IEC 61000-4-5 level 3: Surge
  • IEC 61000-4-6 level 3: Conducted Radio Frequency
  • IEC 61000-4-8: Power Frequency Magnetic Field
  • Meets ANSI/IEEE C37.90.1: Fast Transient SWC

Electromagnetic Emission:

  • Designed to comply with IEC 61000-6-4: Radiated/Conducted class B
  • Designed to comply with IEC CISPR 22: Radiated/Conducted class B

Safety/Construction:

  • Meets IEC/UL 61010-1, 3rd ed.
  • AC and Impulse Insulation:
    • Designed to comply with AS/IEC 62052-11
    • 4000 VAC during 1 minute
    • 2KV/500Ω @ 1.2/50 μs impulse

eXpertPRO EM235 Power Quality Analyser Technical Specifications

eXpertPRO DIN EM235 Technical Specifications
SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Terms & Conditions
  • Privacy Policy

Recent Posts

  • Industry requires smart metering standards to continually evolve.

    The Evolution of Smart Metering Standards: What’s Next for Compliance and Innovation?

    Smart metering has revolutionised the way energy is measured, managed and consumed. With its ability to provide real-time data on energy usage, smart metering plays a vital role in modernising energy grids and improving the efficiency of energy markets. However, as this technology continues to evolve, so too must the standards that govern it.

    11 March, 2025
  • Sustainable building with vertical gardens

    High Precision Metering for NABERS & J9 Compliance

    Achieving superior energy efficiency in buildings is not just about measurement—it’s about measurement accuracy. In Australia, compliance with NABERS (National Australian Built Environment Rating System) and J9 standards under the National Construction Code (NCC) 2022 demands reliable energy data.

    27 February, 2025
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • About SATEC
  • HARDWARE
    • Phasor Measurement Unit
    • Power Quality Analysers
    • NMI Approved Energy Meters
    • Multi-Channel Energy Meters
    • Current Transformers
    • Expansion Modules
    • All Metering Products
  • SOFTWARE
    • Power Analysis Software (PAS)
    • eXpertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
  • SOLUTIONS
    • Power of Choice Metering
    • NMI Approved Retrofit Energy Metering
    • Frequency Control Ancillary Services (FCAS)
    • Disturbance Direction Detection
    • Phasor Measurement Unit
    • Automatic Demand Response
    • Large-Scale Generation Certificates (LGCs)
  • NEWS
  • DOWNLOADS
    • Manuals & Datasheets
    • Billing & Revenue Metering Catalogue
    • Power Analysis Software (PAS)
    • Current Product Catalogue
  • CONTACT
SATEC (Australia) Pty Ltd