+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC

EXPANSION MODULES

SATEC metering EM13x, PM130/135 have RS485 communications as standard.
Dual simultaneous communications can be incorporated with expanded add-on modules along with I/O capabilities.

Communication Modules

RS232/422/485

RS232/422/485 – DIN

Ethernet

Ethernet-DIN

4G Modem

4G Modem – DIN

Profibus

Input / Output Modules

4 Digital Inputs & 2 Relay Outputs

4 Digital Inputs & 2 Digital Outputs

4 Digital Inputs with Battery BackUp for TOU

8 Digital Input

12 Digital Inputs & 4 Relay Outputs

12 Digital Inputs & 4 Relay Outputs with RS485 Comms

12 Digital Inputs & 4 Relay Outputs with Ethernet Comms

4 Analogue Outputs

Downloads

eXpertmodules™ Expansion Modules Datasheet

EM133-XM Smart Energy Meter

Expansion Modules

Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

RS232/422/485

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

RS232

Image available soon

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

RS232/422/485 - DIN

EM132/133

EM133-AR

EM133-XM

72x46x34mm

RS232-DIN

4 Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

Ethernet

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

ETH

Ethernet DIN Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

Ethernet-DIN

EM132/133

EM133-AR

EM133-XM

90x30x75mm

ETHD

Image available soon

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4G Modem

EM132/133

EM133-AR

EM133-XM

PM130/135

Currently not available for the Australian market

Image available soon

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4G Modem - DIN

EM132/133

EM133-AR

EM133-XM

Currently not available for the Australian market

Profibus expansion module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

Profibus

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

PRO

Input / Output Modules

4-Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4 Digital Inputs & 2 Relay Outputs

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

DIOR

4-Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4 Digital Inputs & 2 Digital Outputs

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

DIOS

4-Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4 Digital Inputs with Battery BackUp for TOU

PM130/135

72x46x34mm

TOD

Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

8 Digital Input

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

8DI

Input Output Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

12 Digital Inputs & 4 Relay Outputs

EM132/133

EM133-AR

EM133-XM

PM130/135

95×77×45mm

12DIOR-xxx (xxx = Dry or Wetted Contact Options)

Input Output Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

12 Digital Inputs & 4 Relay Outputs RS485

EM132/133

EM133-AR

EM133-XM

PM130/135

95×77×45mm

12DIOR-xxx-485 (xxx = Dry or Wetted Contact Options)

Input Output Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

12 Digital Inputs & 4 Relay Outputs Ethernet

EM132/133

EM133-AR

EM133-XM

PM130/135

95×77×45mm

12DIOR-xxx-ETH (xxx = Dry or Wetted Contact Options)

Analogue Expansion Module

Description:

Meter Model:

Dimensions (H x W x D):

Order Code:

4 Analogue Outputs

EM132/133

EM133-AR

EM133-XM

PM130/135

72x46x34mm

AOx (x = Analogue Output Options)

Discuss your metering needs with us

SATEC (Australia) Pty Ltd

We look forward to discussing your next project. Fill out the form or pick up the phone, we will be happy to help.

PO Box 82, Mulgoa NSW 2745

Phone: +61 2 4774-2959

Email: [email protected]

    SATEC Australia logo

    SATEC – Solutions And Technology for Energy Control

    SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

    The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

    Quick Find

    • Contact
    • Metering Products
    • Energy Management Software
    • News – Events – Updates
    • Downloads
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Energy Management Knowledge Base
    • Terms & Conditions
    • Privacy Policy

    Recent Posts

    • Power Metering for Hospitals and Healthcare Facilities

      Discover how power metering helps hospitals improve reliability, cut energy costs and support decarbonisation. SATEC’s metering solutions support critical healthcare facilities.

      10 December, 2025
    • Why Choosing the Right Electricity Sub Meter Matters for Accurate Billing

      Choosing the right electricity sub meter is essential for accurate, compliant energy billing and tenant trust. Discover what to look for and how SATEC’s sub metering solutions can help.

      9 December, 2025
    © 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
    • HARDWARE
      • All Metering Products
      • Current Transformers
      • DC Energy Metering
      • Expansion Modules
      • Frequency Control Ancillary Services – FCAS
      • Multi-Channel Energy Meters
      • NMI Approved Energy Meters
      • Phasor Measurement Unit
      • Power Quality Analysers
    • SOFTWARE
      • Expertpower SaaS – EMS, Billing, Power Quality
      • Meter Data Management (MDM)
      • Power Analysis Software (PAS)
    • SOLUTIONS
      • Automatic Demand Response
      • Disturbance Direction Detection
      • Frequency Control Ancillary Services (FCAS)
      • Large-Scale Generation Certificates (LGCs)
      • NMI Approved Retrofit Energy Metering
      • Phasor Measurement Unit
      • Power of Choice Metering
      • Time of Use (TOU) Control
    • NEWS
    • DOWNLOADS
      • Billing & Revenue Metering Catalogue
      • Current Product Catalogue
      • Manuals & Datasheets
      • Power Analysis Software (PAS)
    • CONTACT
      • About SATEC
    SATEC (Australia) Pty Ltd