+61 2 4774-2959
[email protected]
  • About SATEC
  • Billing & Revenue Metering Catalogue
SATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty LtdSATEC (Australia) Pty Ltd
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC

FREQUENCY CONTROL ANCILLARY SERVICES - FCAS

Very Fast, Fast, Slow, Delayed solutions for FCAS

SATEC PRO Series Advanced Power Meters

SATEC’s new PRO assists with compliance to AEMO’s Market Ancillary Service Specification (MASS) for FCAS markets. 

The PRO has two (2) separate models for either Real-Time Data or Internal Data Recording.

All FCAS markets are possible: Very Fast, Fast, Slow, Delayed & Regulation.

FCAS DatasheetCONTACT US

Real-Time Data

Accuracy Class 0.2S

0.0001 Hz

4 decimal places – Frequency

20 ms – Modbus RTU/TCP

1 second – Modbus RTU/TCP

1 second – IEC 61850 (0.001 Hz)

IEC 61557-12

NATA Test Certificates

SLOW & VERY SLOW

Accuracy Class 0.2S

0.0001 Hz

4 decimal places – Frequency

1 second recording period

20 second before FDT and 10 minutes after FDT

IEC 61557-12

NATA Test Certificates

FAST & VERY FAST

Accuracy Class 0.2S

0.0001 Hz

4 decimal places – Frequency

20 ms recording period

5 second before FDT and 60 seconds after FDT

IEC 61557-12

NATA Test Certificates

MASS Compliance - Very Fast, Fast, Slow, Delayed

Market ancillary service specification compliance for recording period for Power & System Frequency Measurements

0.0001 Hertz Resolution

Class 0.2S accuracy according to IEC 62053-22

4 decimal place - Frequency

NATA Test Certificates

Programmable Logic Controller (PLC)

PLC embedded controller for advanced solutions

eXpertPRO DIN EM3250

Communication Options

Dual Ethernet TCP/IP (standard)

RS-485 master/slave (standard)

USB C (standard)

InfraRed (standard)

4G CAT-M integrated modem (future)

Communication Protocols

IEC 61850 + GOOSE

Modbus RTU

Modbus ASCII

Modbus TCP

IEC 60870-5-101

IEC 60870-5-104

SATEC Australia logo

SATEC – Solutions And Technology for Energy Control

SATEC’s presence in Australia brings together 40 plus years of experience and knowledge for Energy Management Solutions.

The culmination of local expertise and SATEC’s Global leadership in metering, power quality analysers and software provides a source of knowledge to satisfy customer’s ever changing demands for today’s Energy and Power Quality Applications.

Quick Find

  • Contact
  • Metering Products
  • Energy Management Software
  • News – Events – Updates
  • Downloads
  • Billing & Revenue Metering Catalogue
  • Current Product Catalogue
  • Energy Management Knowledge Base
  • Terms & Conditions
  • Privacy Policy

Recent Posts

  • The outside of the Sydney Eye Hospital where Current Transformer Metering for Retrofit Projects are particularly relevant

    Current Transformer Metering for Retrofit Projects: Solving Space and Access Constraints

    Current transformer metering makes retrofit energy monitoring possible when switchboards are tight on space and access. Learn how CTs reduce disruption and improve visibility.

    9 February, 2026
  • Two retirement village tenants sitting outside a unit building where Power Consumption Metering for Tenancy Billing is crucial when invoicing for energy usage

    Power Consumption Metering for Tenancy Billing: What “Meter for Trade” Means

    Power consumption metering for tenancy billing in Australia: what “meter for trade” means, when you need it and how SATEC meters + Expertpower support compliant billing.

    6 February, 2026
© 2025 SATEC (Australia) Pty Ltd. | ABN 21-142640417 | SATEC® All Rights Reserved
  • HARDWARE
    • All Metering Products
    • Current Transformers
    • DC Energy Metering
    • Expansion Modules
    • Frequency Control Ancillary Services – FCAS
    • Multi-Channel Energy Meters
    • NMI Approved Energy Meters
    • Phasor Measurement Unit
    • Power Quality Analysers
  • SOFTWARE
    • Expertpower SaaS – EMS, Billing, Power Quality
    • Meter Data Management (MDM)
    • Power Analysis Software (PAS)
  • SOLUTIONS
    • Automatic Demand Response
    • Disturbance Direction Detection
    • Frequency Control Ancillary Services (FCAS)
    • Large-Scale Generation Certificates (LGCs)
    • NMI Approved Retrofit Energy Metering
    • Phasor Measurement Unit
    • Power of Choice Metering
    • Time of Use (TOU) Control
  • NEWS
  • DOWNLOADS
    • Billing & Revenue Metering Catalogue
    • Current Product Catalogue
    • Manuals & Datasheets
    • Power Analysis Software (PAS)
  • CONTACT
    • About SATEC
SATEC (Australia) Pty Ltd