1 00:00:00,080 --> 00:00:04,250 A site is a file on your PC that tells PAS which meter to use. 2 00:00:04,720 --> 00:00:07,600 Let's create one for this EM235. 3 00:00:08,240 --> 00:00:13,200 Start offline, open Tools, then Configuration, and select Sites. 4 00:00:13,440 --> 00:00:16,000 In your Demo folder, enter a short name. 5 00:00:16,400 --> 00:00:18,880 We'll use EM235 New. 6 00:00:19,360 --> 00:00:20,160 Choose New. 7 00:00:20,480 --> 00:00:23,300 Select the new file in the list, then choose OK. 8 00:00:23,920 --> 00:00:24,800 Check the model. 9 00:00:25,120 --> 00:00:28,960 This blank file initially shows PM172-N. 10 00:00:29,640 --> 00:00:31,780 Change it to EM235. 11 00:00:32,340 --> 00:00:34,510 Select Internet Site for the network connection. 12 00:00:34,740 --> 00:00:36,900 Our meter uses device address 1. 13 00:00:37,140 --> 00:00:40,860 These settings describe this demonstration meter, so use the details 14 00:00:40,860 --> 00:00:42,760 for your own meter when you follow along. 15 00:00:43,230 --> 00:00:46,460 Open the Connection tab and enter your meter's IP address. 16 00:00:46,720 --> 00:00:52,360 Our example is 192.168.1.203. 17 00:00:52,800 --> 00:00:56,000 Leave the host port at 502 for this direct connection, 18 00:00:56,000 --> 00:00:57,760 and check the protocol shown here. 19 00:00:58,240 --> 00:00:59,290 Choose OK. 20 00:00:59,520 --> 00:01:03,360 Reopen Configuration to check that the model and connection details were saved. 21 00:01:03,730 --> 00:01:08,080 Next, close Configuration and open Monitor, then Communication Test. 22 00:01:08,480 --> 00:01:10,960 This test is available with On line switched off. 23 00:01:11,310 --> 00:01:12,470 Choose Edit Request. 24 00:01:12,870 --> 00:01:16,180 For this EM235, select function 3, 25 00:01:16,550 --> 00:01:20,470 start register 46100, and word count 2. 26 00:01:20,870 --> 00:01:24,630 These are fixed firmware values listed in this model’s communication manual. 27 00:01:25,030 --> 00:01:27,240 Choose OK, then Send. 28 00:01:27,750 --> 00:01:28,950 Two values return. 29 00:01:29,670 --> 00:01:33,750 Send again: the values stay the same, the OK count increases, 30 00:01:33,750 --> 00:01:35,670 and the error counts remain at zero. 31 00:01:36,310 --> 00:01:39,190 PAS is receiving replies from the meter. 32 00:01:39,700 --> 00:01:42,500 Close the test, open Monitor, and select On line. 33 00:01:42,640 --> 00:01:44,800 Right click your site and choose Properties. 34 00:01:44,800 --> 00:01:49,040 Here you can check the model, online status, serial number, and firmware. 35 00:01:50,240 --> 00:01:53,440 Compare the serial number with the label on your meter before changing 36 00:01:53,440 --> 00:01:54,180 its settings. 37 00:01:54,800 --> 00:01:57,360 A successful reply confirms communication. 38 00:01:57,760 --> 00:02:01,120 Checking the serial number helps confirm you have the right meter. 39 00:02:01,360 --> 00:02:03,210 Here’s a useful shortcut for later: 40 00:02:03,840 --> 00:02:05,700 expand the plus beside your site, 41 00:02:06,050 --> 00:02:08,780 then expand General Setup to see its setup pages. 42 00:02:09,010 --> 00:02:11,490 Return to offline mode when you finish this check. 43 00:02:11,840 --> 00:02:14,930 Next, upload the meter's settings to make your first backup.