1 00:00:00,000 --> 00:00:04,420 Expertpower brings meter readings, consumption, events and other views 2 00:00:04,420 --> 00:00:05,760 together. 3 00:00:05,760 --> 00:00:09,780 The useful starting point is a simple question: which meter do I want to 4 00:00:09,780 --> 00:00:12,440 inspect, and what do I want to know? 5 00:00:12,440 --> 00:00:17,420 In this lesson, we will explore the site tree, use all seven shortcuts on 6 00:00:17,420 --> 00:00:20,940 a device menu, and compare them with the main menus. 7 00:00:20,940 --> 00:00:24,820 Our example is the existing SATEC demo site. 8 00:00:24,820 --> 00:00:27,180 We will keep its names and settings as they are. 9 00:00:27,700 --> 00:00:30,400 Expand SATEC, then Demo Site. 10 00:00:30,400 --> 00:00:35,200 Open PM180 SATEC Income to reveal the records 11 00:00:35,200 --> 00:00:39,120 underneath, including Communication room-9, Main air 12 00:00:39,120 --> 00:00:42,840 conditioning, Main Lightning, Production hall and Workstations 13 00:00:42,840 --> 00:00:44,120 sockets. 14 00:00:44,120 --> 00:00:48,720 SATEC Main PM335 is another entry beside that 15 00:00:48,720 --> 00:00:50,080 branch. 16 00:00:50,080 --> 00:00:54,560 The indentation shows the hierarchy presented by this site. 17 00:00:54,560 --> 00:00:59,460 Expanding a branch reveals its contents; selecting a device chooses the 18 00:00:59,460 --> 00:01:01,800 data you want to inspect. 19 00:01:01,800 --> 00:01:05,540 Look at Current Selection to confirm the device name. 20 00:01:05,540 --> 00:01:09,360 An open branch alone does not mean that every device beneath it is selected. 21 00:01:10,067 --> 00:01:15,067 For a larger tree, the search saves repeated expanding and scrolling. 22 00:01:15,067 --> 00:01:19,467 Open Device Tree, choose its magnifier, type Main air, and press 23 00:01:19,467 --> 00:01:21,607 Enter. 24 00:01:21,607 --> 00:01:25,487 The result shows Main air conditioning under SATEC and PM180 25 00:01:25,487 --> 00:01:28,647 SATEC Income. 26 00:01:28,647 --> 00:01:32,907 Select the result to open its path and choose the device. 27 00:01:32,907 --> 00:01:34,967 Check Current Selection again. 28 00:01:34,967 --> 00:01:38,247 We will follow this same device through the next views. 29 00:01:38,247 --> 00:01:42,927 Some destinations display its site as Submeters, so use the device 30 00:01:42,927 --> 00:01:46,647 identity as well as the displayed site name to check your context. 31 00:01:47,333 --> 00:01:52,233 Move to the three dots beside Main air conditioning and open the device menu. 32 00:01:52,233 --> 00:01:56,333 It offers Device details, Last Reading, Consumption, 33 00:01:56,333 --> 00:02:00,133 Events, History, Waveforms and Billing. 34 00:02:00,133 --> 00:02:05,113 Device details opens the administrative information for this record. 35 00:02:05,113 --> 00:02:09,633 Here, we inspect the page and return without submitting a change. 36 00:02:09,633 --> 00:02:12,873 Last Reading shows the latest available measurements. 37 00:02:12,873 --> 00:02:17,613 Consumption shows energy information over a reporting period. 38 00:02:17,613 --> 00:02:20,893 History lets us follow recorded measurements over time. 39 00:02:20,893 --> 00:02:25,093 Each answers a different question, using the selected meter as the starting 40 00:02:25,093 --> 00:02:25,513 point. 41 00:02:25,967 --> 00:02:29,447 Here is the other way to reach those monitoring views. 42 00:02:29,447 --> 00:02:33,467 Select the device in the tree, then use the main menus. 43 00:02:33,467 --> 00:02:37,187 Readings, then Last Reading opens its readings view. 44 00:02:37,187 --> 00:02:40,627 Consumption, then Electricity, then Total opens 45 00:02:40,627 --> 00:02:42,407 consumption. 46 00:02:42,407 --> 00:02:45,627 Readings, then History opens the history view. 47 00:02:45,627 --> 00:02:49,067 We have now used the device shortcut and the ordinary menu for the same 48 00:02:49,067 --> 00:02:50,147 device. 49 00:02:50,147 --> 00:02:54,607 Check the reporting dates, quantity and units after navigating. 50 00:02:54,607 --> 00:02:59,127 Browser Back returns us to an earlier view, although the navigation trail can 51 00:02:59,127 --> 00:03:02,087 lag behind the page body in this demo. 52 00:03:02,087 --> 00:03:05,007 Use the main menu when you need to confirm the destination. 53 00:03:05,833 --> 00:03:10,393 The Events shortcut is a useful reminder to check scope. 54 00:03:10,393 --> 00:03:14,353 We start with Main air conditioning selected, but this destination shows All 55 00:03:14,353 --> 00:03:15,913 Customers. 56 00:03:15,913 --> 00:03:20,413 Events, then Event Summary reaches that broader view too. 57 00:03:20,413 --> 00:03:24,133 Do not read those results as events belonging only to the meter we started 58 00:03:24,133 --> 00:03:25,793 from. 59 00:03:25,793 --> 00:03:30,153 When we return through Readings, then Last Reading, Main air conditioning is 60 00:03:30,153 --> 00:03:31,893 selected again. 61 00:03:31,893 --> 00:03:35,593 Current Selection tells us what the screen is actually using. 62 00:03:35,900 --> 00:03:39,500 Waveforms takes us to the power-quality waveform view. 63 00:03:39,500 --> 00:03:43,380 The main-menu route is Power Quality, then Waveforms. 64 00:03:43,380 --> 00:03:47,580 Both routes identify Main air conditioning, and this demo device reports 65 00:03:47,580 --> 00:03:51,220 No Data Available for this device. 66 00:03:51,220 --> 00:03:54,460 That message describes the available result; it is not a 67 00:03:54,460 --> 00:03:56,320 diagnosis. 68 00:03:56,320 --> 00:03:59,880 Billing opens Billing Data for the selected device. 69 00:03:59,880 --> 00:04:04,140 We can also reach that destination through Billing, then Billing Data. 70 00:04:04,140 --> 00:04:09,080 This lesson shows the route and device context; the detailed billing workflow 71 00:04:09,080 --> 00:04:10,660 belongs in its own lesson. 72 00:04:11,067 --> 00:04:13,487 The tree chooses your context. 73 00:04:13,487 --> 00:04:16,467 The three dots provide convenient shortcuts. 74 00:04:16,467 --> 00:04:20,167 The main menus provide another way to reach the available views. 75 00:04:20,167 --> 00:04:23,887 Choose the record, open the view, then check the selection and reporting 76 00:04:23,887 --> 00:04:25,287 dates. 77 00:04:25,287 --> 00:04:29,667 That small habit makes a busy monitoring system much easier to navigate. 78 00:04:29,667 --> 00:04:33,727 In the Groups lesson, we will save useful sets of devices so that repeated 79 00:04:33,727 --> 00:04:35,867 reviews take fewer selection steps.