1 00:00:00,067 --> 00:00:01,567 How much power was this meter 2 00:00:01,567 --> 00:00:03,767 recording and when did it change? 3 00:00:04,400 --> 00:00:07,400 Expertpower's History view helps you answer 4 00:00:07,400 --> 00:00:10,000 that question without changing the meter. 5 00:00:10,467 --> 00:00:12,467 This is the SATEC Demo Site, 6 00:00:12,467 --> 00:00:14,167 Using the existing record 7 00:00:14,167 --> 00:00:17,367 called PM180 SATEC Income. 8 00:00:17,600 --> 00:00:20,467 we are demonstrating how to read the screen. 9 00:00:20,467 --> 00:00:22,933 The record name alone does not prove 10 00:00:22,933 --> 00:00:25,433 the equipment connected behind it. 11 00:00:25,433 --> 00:00:29,133 From Manager, open Readings, then History. 12 00:00:29,133 --> 00:00:30,567 Check current selection 13 00:00:30,567 --> 00:00:32,700 before interpreting the graph. 14 00:00:32,967 --> 00:00:35,533 Confirm the site and the device and keep 15 00:00:35,533 --> 00:00:38,000 that context visible as you work. 16 00:00:38,667 --> 00:00:41,533 Choose a completed day. Here, 17 00:00:41,533 --> 00:00:43,967 The reporting range runs from midnight 18 00:00:43,967 --> 00:00:47,200 on the tenth of November to midnight on the eleventh. 19 00:00:47,600 --> 00:00:48,967 Read both boundaries, 20 00:00:48,967 --> 00:00:50,800 then apply the selection. 21 00:00:51,367 --> 00:00:54,667 Dates are shown month first in this interface. 22 00:00:54,667 --> 00:00:56,033 Under data type, 23 00:00:56,033 --> 00:00:57,067 choose Phase, 24 00:00:57,067 --> 00:00:58,700 then Active Power. 25 00:00:59,300 --> 00:01:02,700 The unit is kilowatts. Power describes 26 00:01:02,700 --> 00:01:05,233 the rate of energy use at a reading. 27 00:01:05,633 --> 00:01:07,700 Energy measured in kilowatt 28 00:01:07,700 --> 00:01:10,033 hours accumulates over time. 29 00:01:10,433 --> 00:01:12,267 A power reading and an energy 30 00:01:12,267 --> 00:01:15,033 total answer different questions. 31 00:01:15,300 --> 00:01:17,633 The legend identifies phase one, 32 00:01:17,633 --> 00:01:19,900 Phase two, and phase three. 33 00:01:20,133 --> 00:01:22,367 These are phases of the selected record, 34 00:01:22,367 --> 00:01:24,467 not three separate sites. 35 00:01:24,467 --> 00:01:27,367 Clicking a legend entry hides that trace. 36 00:01:27,733 --> 00:01:30,233 Hide the other two to inspect phase one, 37 00:01:30,233 --> 00:01:31,333 then click them again 38 00:01:31,333 --> 00:01:33,167 to restore the comparison. 39 00:01:34,133 --> 00:01:35,567 A hidden trace is not 40 00:01:35,567 --> 00:01:37,433 evidence of a dead phase. 41 00:01:37,900 --> 00:01:40,033 Look at the time axis and the summary 42 00:01:40,033 --> 00:01:42,733 together on this displayed day. 43 00:01:42,733 --> 00:01:47,033 Phase one's maximum is 37.54 kilowatts. 44 00:01:47,500 --> 00:01:48,867 That is the maximum shown 45 00:01:48,867 --> 00:01:50,667 for this history selection. 46 00:01:51,633 --> 00:01:53,633 It does not automatically establish 47 00:01:53,633 --> 00:01:56,100 the maximum demand used for billing. 48 00:01:56,767 --> 00:01:58,767 To inspect part of the profile, 49 00:01:58,767 --> 00:02:01,400 hold the left mouse button inside the plot 50 00:02:01,400 --> 00:02:03,233 drag across the time window. 51 00:02:03,233 --> 00:02:06,600 then release. The plotted hours 52 00:02:06,600 --> 00:02:09,133 narrow and Reset Zoom appears. 53 00:02:09,133 --> 00:02:12,000 The reporting dates at the top stay the same. 54 00:02:12,433 --> 00:02:14,167 Click Reset Zoom to restore 55 00:02:14,167 --> 00:02:16,067 the whole day's context. 56 00:02:16,433 --> 00:02:18,233 The details table gives 57 00:02:18,233 --> 00:02:20,533 each reading its own timestamp. 58 00:02:20,833 --> 00:02:23,033 For example, the midnight row 59 00:02:23,033 --> 00:02:26,667 shows 10.31 kilowatts for phase one. 60 00:02:27,067 --> 00:02:28,600 Always read across the same 61 00:02:28,600 --> 00:02:30,533 row and check the units. 62 00:02:31,000 --> 00:02:33,600 Do not assume every timestamp is exactly 63 00:02:33,600 --> 00:02:35,833 on a quarter hour or that a joined 64 00:02:35,833 --> 00:02:37,800 line proves complete data. 65 00:02:38,533 --> 00:02:39,700 For demand fields, 66 00:02:39,700 --> 00:02:41,333 choose Power and Demand, 67 00:02:41,333 --> 00:02:43,333 then Total Demands. 68 00:02:43,333 --> 00:02:45,167 Read the full field name. 69 00:02:45,167 --> 00:02:46,967 Power Demand and Maximum Power 70 00:02:46,967 --> 00:02:48,967 Demand are separate entries. 71 00:02:49,733 --> 00:02:51,733 Kilowatts and kilovolt amperes 72 00:02:51,733 --> 00:02:53,233 are different units. 73 00:02:53,500 --> 00:02:56,467 Before using a demand figure for a decision, 74 00:02:56,467 --> 00:02:58,867 confirm the meter's demand interval 75 00:02:58,867 --> 00:03:01,567 calculation method and reset history. 76 00:03:02,600 --> 00:03:03,867 Those settings have not 77 00:03:03,867 --> 00:03:06,200 been established by this demonstration. 78 00:03:06,767 --> 00:03:08,400 Return to phase and choose 79 00:03:08,400 --> 00:03:11,167 PF to inspect power factor. 80 00:03:11,700 --> 00:03:13,867 Preserve the displayed sign. 81 00:03:13,867 --> 00:03:15,900 A minus sign on its own is not 82 00:03:15,900 --> 00:03:18,200 a diagnosis of reverse energy, 83 00:03:18,200 --> 00:03:20,833 incorrect wiring, or a fault. 84 00:03:21,233 --> 00:03:22,800 Check the meter's documented 85 00:03:22,800 --> 00:03:24,567 convention and supporting measurements 86 00:03:24,567 --> 00:03:26,267 before interpreting it. 87 00:03:26,833 --> 00:03:29,233 Use the same sequence each time. 88 00:03:29,467 --> 00:03:32,100 Check the selected record and period 89 00:03:32,100 --> 00:03:33,667 choose the quantity and unit, 90 00:03:33,667 --> 00:03:35,467 inspect the graph and confirm 91 00:03:35,467 --> 00:03:37,400 the timestamped details. 92 00:03:38,467 --> 00:03:39,800 You now have a precise 93 00:03:39,800 --> 00:03:41,733 observation to investigate 94 00:03:41,733 --> 00:03:44,567 rather than a conclusion based on one line.