# PM175 power quality analyser datasheet (LED display): specifications and ordering codes

> PM175 datasheet as a web page: Power Quality Analyser and Revenue Meter with Detachable LED Display. Specifications, ordering codes and standards, transcribed from SATEC Australia datasheet TBV1.0.

Source page: https://satec-global.com.au/support/datasheets/pm175-led/

---

PM175 · DATASHEET

# PM175 power quality analyser datasheet (LED display)

Power Quality Analyser and Revenue Meter with Detachable LED Display.

Transcribed from the SATEC Australia datasheet [TBV1.0, 29 September 2026](https://satec-global.com.au/documentation/PM175-LED-Power-Quality-Analyser-Datasheet-TBV1-0.pdf) (PDF, 5 pages, 439 KB). If this page and the PDF differ, the PDF is right; tell us through the [contact form](https://satec-global.com.au/contact/).

## Overview

Superseded: this meter has been superseded by the PRO Series PM175. This datasheet is kept for existing installations and support. For new projects see the PM175 PRO.

The PM175 is a compact multifunction three-phase AC power meter and power quality analyser. It was designed for users ranging from electrical panel builders to substation operators who need revenue-grade energy data and EN 50160 power quality reporting in one instrument.

A bright three-row LED display gives clear local readings. The display module is detachable and can be mounted up to 1000 m from the meter. Two communication ports support local and remote meter reading and setup over serial lines, LAN and the internet.

## Current input options

- 

### 5A CT Input

5A secondary current inputs with a 10A continuous operating range.

- 

### 1A CT Input

1A secondary current inputs with a 2A continuous operating range.

- 

### Remote Display

Detachable 3-row LED module. An LCD colour touch screen was optional.

## Main features

- Class 0.2S revenue accuracy per AS/IEC 62053-22
- 128 samples per cycle true RMS measurement
- Fast real-time cycle-by-cycle measurements
- Four-quadrant energy and power measurement
- Built-in EN 50160 power quality reports
- Harmonics and inter-harmonics to the 50th order
- Two simultaneous waveform recorders
- Time-of-Use metering with 8 tariffs and 4 seasons
- 1 MB of non-volatile log memory
- 2 relay outputs and 4 digital inputs
- Optional analogue inputs and outputs
- Two communication ports including Ethernet

## Feature capabilities

### Measurements

- Class 0.2S revenue accuracy
- 128 samples per cycle true RMS measurements
- Fast real-time cycle-by-cycle measurements
- Four-quadrant measurements
- Min/Max values for instantaneous and demand readings
- Accepts all wiring configurations, selectable from the front panel or via communications

### Energy and Time-of-Use

- Class 0.2S active and apparent energy per AS/IEC 62053-22:2003
- 8 totalisation and tariff energy/demand registers x 8 tariffs
- 4 seasons x 4 types of day with 8 tariff changes per day
- Easily programmable tariff schedule
- Automatic daily profile of energy and maximum demand readings for total and tariff registers

### EN 50160 Power Quality Recorder

- EN 50160 compliance statistics and harmonics survey statistics
- Onboard power quality analyser with programmable thresholds and hysteresis
- Ready-to-use reports
- Customisable EN 50160 power quality recorder
- IEEE 519 power quality evaluation
- Flicker measurement per IEC 61000
- Sag/swell detection and automatic reporting

### Full Harmonic Analyser

- Individual voltage and current harmonics up to the 50th order
- Voltage inter-harmonics up to the 50th order
- Voltage and current THD, current TDD and K-factor
- Power harmonics and harmonic flow (direction of harmonics)
- Voltage and current harmonic spectrum and angles
- Conforms with harmonic standards IEEE 1159 and G5/4

### Waveform and Transient Recording

- Two independent simultaneous waveform recorders
- Each records complete three-phase voltage and current waveforms
- Recording resolution from 32 up to 128 samples per cycle
- Up to 16 pre-fault and up to 2000 post-fault cycles
- Transient recording with a minimum width of 156 µs at 50 Hz
- Programmable memory partition

### Event and Data Logging

- Programmable event log with 1 ms time stamp
- 16 programmable data log tables with up to 16 parameters each
- Record intervals from 1 to 9999 seconds
- 1 MB of non-volatile log memory
- Fully programmable memory partition for event, data and waveform logs

### Real-Time Clock

- Real-time clock for time-stamped event, data and waveform logs
- Typical error of 15 seconds per month at 25°C
- Synchronisation with a GPS pulse input

### Control and I/O

- 2 relay outputs
- 4 digital inputs
- 4 analogue inputs (optional)
- Up to 16 analogue outputs (optional)

### Communications

- Two independent communication ports
- COM1: RS232/422/485 or Ethernet 10/100BaseT
- COM2: RS422/485
- Modbus RTU, Modbus ASCII, Modbus TCP/IP, DNP3 and Profibus DP
- MV90xi compatible

### Software Support

- PAS Power Analysis Software for setup, data retrieval and analysis
- Expertpower web platform via the Ethernet port
- eXpertConnect™ App for mobile access to energy data

Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.

## Specifications

Construction
| Dimensions |Height 114 mm, width 127 mm, length 114 mm |
| Weight |1.23 kg (2.7 lb) |
| Display |Bright 3-row LED display, detachable and mountable up to 1000 m from the meter |
| Optional display |LCD colour touch screen graphical display |

Voltage inputs
| Operating range |690V AC line-to-line, 400V AC line-to-neutral |
| Connection |Direct or via PT (up to 828V AC line-to-line, up to 480V AC line-to-neutral) |

Current inputs · 5A secondary
| Operating range |10A RMS continuous |
| Burden |<0.1 VA |
| Overload withstand |15A RMS continuous, 300A RMS for 1 second |

Current inputs · 1A secondary
| Operating range |2A RMS continuous |
| Burden |<0.02 VA |
| Overload withstand |6A RMS continuous, 80A RMS for 1 second |

General
| Frequency |15 Hz to 480 Hz |
| Burden |8 VA |
| Operating temperature |-20°C to +60°C |
| Humidity |0 to 95% non-condensing |
| Real-time clock |Typical error 15 seconds per month at 25°C |

Inputs and outputs
| Relay outputs |2 relays rated 3A/250V AC and 3A/30V DC, 2 contacts (SPST Form A) |
| Digital inputs |4 |
| Analogue inputs |4 (optional) |
| Analogue outputs |Up to 16 (optional) |
| Analogue ranges |±1 mA, 0-1 mA, 0-20 mA, 4-20 mA |

Energy and accuracy
| Accuracy class |Class 0.2S per AS/IEC 62053-22:2003 |
| Revenue accuracy |Per ANSI C12.20-1998 |
| Time-of-Use |8 totalisation and tariff energy/demand registers x 8 tariffs, 4 seasons x 4 types of day, 8 tariff changes per day |
| Daily profile |Automatic daily profile of energy and maximum demand readings |

Communications
| Ports |Two independent communication ports |
| COM1 |RS232/422/485 or Ethernet 10/100BaseT |
| COM2 |RS422/485 |
| RS485 |Up to 32 devices |
| Protocols |Modbus RTU, Modbus ASCII, Modbus TCP/IP, DNP3, Profibus DP |

Memory and logging
| Log memory |1 MB non-volatile |
| Data logs |16 tables, up to 16 parameters each, 1 to 9999 s intervals |
| Waveform logs |2 recorders, 32 to 128 samples per cycle |
| Event log |1 ms time stamp |

Warranty
| Product warranty |3 years |
| Warranty of accuracy |10 years |

Measurement accuracy
| Voltage (10-120% FS) |0.2% |
| Current (10-200% FS), starting current 0.1% FS |0.2% |
| Neutral current |0.4% |
| Frequency |0.02% |
| Power factor |0.2% |
| Active power (W) |0.2% |
| Reactive power (var) |0.3% |
| Apparent power (VA) |0.2% |
| Active energy (Wh) |Class 0.2S per AS/IEC 62053-22:2003 |
| Reactive energy (varh) |Class 0.2S under conditions per AS/IEC 62053-22:2003, |PF| < 0.9 |
| Apparent energy (VAh) |Class 0.2S per AS/IEC 62053-22:2003 |
| Total harmonic distortion (THD) |0.1% |
| Total demand distortion (TDD) |1.5% |
| Temperature coefficient |0.008%/°C |
| Input circuit consumption |Less than 0.1 VA |
| Measured current range |1% to 200% |

Printed column headings: Parameter; Accuracy (Reading).

## Standards compliance

### Accuracy

- AS/IEC 62053-22:2003 Class 0.2S
- ANSI C12.20-1998

### Power quality

- EN 50160
- IEC 61000-4-7 harmonics and inter-harmonics
- IEC 61000 flicker
- CBEMA/ITIC
- IEEE 519 and IEEE 1159

### Emission

- EN 55011:1991
- EN 55022:1994 Class A
- EN 50081-2 Generic Emission Standard, Industrial Environment

### Immunity

- EN 50082-1:1992
- EN 50082-2 Generic Immunity Standard, Industrial Environment
- EN 61000-4-2, EN 61000-4-4:1995, EN 61000-4-8:1993
- ENV 50140:1983, ENV 50141:1993, ENV 50204:1995 (900 MHz)

### Safety

- EN 61010-1:1993/A2:1995

### Directives

- EMC: 89/336/EEC as amended by 92/31/EEC and 93/68/EEC
- LVD: 72/23/EEC as amended by 93/68/EEC and 93/465/EEC

## Ordering information

The PM175 with LED display is no longer offered for new orders. It has been superseded by the PRO Series PM175, which adds Class A power quality measurement per IEC 61000-4-30. SATEC Australia continues to support existing PM175 installations.

## Downloads and related

- [Download the datasheet (PDF, TBV1.0, 439 KB)](https://satec-global.com.au/documentation/PM175-LED-Power-Quality-Analyser-Datasheet-TBV1-0.pdf)
- [Read the PDF in the document library](https://satec-global.com.au/support/documents/doc-b1d5bab242fb/)
- [Product support: answers, documents and videos](https://satec-global.com.au/support/products/pm175/)
- [All datasheets as web pages](https://satec-global.com.au/support/datasheets/)
- [Which PM175 display drawing applies to my panel?](https://satec-global.com.au/support/articles/pm175-display-drawing/)
- [What does the PM175 LED display's CT primary setting mean?](https://satec-global.com.au/support/articles/pm175-led-ct-primary-setting/)
- [Is the PM175 PRO a suitable replacement for my legacy PM175?](https://satec-global.com.au/support/articles/pm175-to-pm175-pro-replacement-checks/)

Questions about this datasheet? Use the [contact form](https://satec-global.com.au/contact/).