# HCS-2000-S Hall effect split-core DC current sensor datasheet: specifications and ordering codes

> HCS-2000-S datasheet as a web page: 2,000A Hall Effect split-core DC current sensor. Specifications, ordering codes and standards, transcribed from SATEC Australia datasheet TBV1.0.

Source page: https://satec-global.com.au/support/datasheets/hcs-2000-s/

---

HCS-2000-S · DATASHEET

# HCS-2000-S Hall effect split-core DC current sensor datasheet

2,000A Hall Effect split-core DC current sensor.

Transcribed from the SATEC Australia datasheet [TBV1.0, 16 September 2026](https://satec-global.com.au/documentation/HCS-2000-S-Hall-Effect-Sensors-Datasheet-TBV1-0.pdf) (PDF, 4 pages, 396 KB). If this page and the PDF differ, the PDF is right; tell us through the [contact form](https://satec-global.com.au/contact/).

## Overview

Based on the Hall Effect principle, the HCS-2000-S is a split-core sensor designed for measuring DC currents up to 2,000A and is designated for a range of SATEC devices featuring DC metering. Its split-core body clamps around an existing conductor without disconnecting it, so it installs quickly on live plant.

The sensor provides high isolation between its primary and secondary circuits, with built-in protection against overvoltage, reversed polarity and electrical disturbances on the output, so it holds up well in demanding industrial and outdoor environments.

## Main features

- High isolation between primary and secondary circuits
- Split-core design for easy installation without disconnecting the conductor
- Protection against overvoltage
- Protection against reversed polarity
- Output protection against electrical disturbances

## Feature capabilities

### Applications

- Photovoltaic applications
- Battery banks, including monitoring load current and charge current and verifying operation
- Transportation, measuring traction power or auxiliary loads
- Industrial instrumentation

Capability depends on the exact model or part number, fitted modules, firmware version, licences and configuration.

## Specifications

General characteristics
| Nominal input current |2,000A |
| Linear measuring range |1.2 × In |
| Overload capacity |5 × In |
| Nominal output signals |±20mA |
| Power supply |+15V DC |
| Current consumption |18mA–50mA + output current |
| Galvanic isolation |6kV RMS/50Hz/min |
| MTBF |≥ 100k hours |

Environmental
| Operating temperature |−40°C to +85°C |
| Storage temperature |−40°C to +100°C |

Accuracy
| Accuracy |±1.0%FS for 300A–999A
±0.5%FS for 2,000A |
| Linearity |±0.5%FS for 300A–999A
±0.2%FS for 2,000A |

Connections
| + |+15V/+12V power supply |
| − |−15V/−12V power supply |
| M |Output |
| G |Ground |

Connections are made via the on-board offset, gain and Phoenix connector terminals shown in the dimensions drawing overleaf.

Construction
| Unit weight |940–980g |

## Ordering information

HCS-2000-S

The HCS-2000-S is a single fixed-specification model with no configurable order options.

## Downloads and related

- [Download the datasheet (PDF, TBV1.0, 396 KB)](https://satec-global.com.au/documentation/HCS-2000-S-Hall-Effect-Sensors-Datasheet-TBV1-0.pdf)
- [Read the PDF in the document library](https://satec-global.com.au/support/documents/doc-56b0a881593b/)
- [All datasheets as web pages](https://satec-global.com.au/support/datasheets/)

Questions about this datasheet? Use the [contact form](https://satec-global.com.au/contact/).